Wiring an Aurus mini split isn't rocket science but it will bite you if you skip the details.
The first thing most people mess up is assuming the wiring diagram is universal across every Aurus model. It's not. The brand uses multiple indoor/outdoor combinations and the terminal assignments change between them. I learned this the hard way on a job where the unit was labeled as a 2023 production run but the wiring inside the outdoor panel matched a 2022 schematic exactly. Wrong terminal connection and you fry the control board. Always open the cover and photograph the label before you touch anything. Most Aurus units use a four-wire communication link between the indoor and outdoor boards. That's LINE 1, LINE 2, ZERO, and GND on the low voltage side, plus the power conductors running hot and neutral through the disconnect. The communication wires are typically 18 gauge stranded and connect to terminals marked Z, A, B, or sometimes just 1, 2, 3 depending on the revision. Some newer models added a dedicated ground terminal on the outdoor PCB that you should actually use instead of bonding through the chassis. The transformer usually steps 240V down to 24V AC for the control circuit. If you're troubleshooting and the indoor unit has no display at all, check the 5 amp fuse on the outdoor board first. That's the most common single point of failure and it costs about two dollars to replace.
I ran into a weird issue last year on a dual-zone Aurus installation where the master outdoor unit wouldn't recognize the second indoor head. The wiring diagram showed both indoor units connecting in parallel to the same communication pair. Everything checked out on the meter. What I finally found was that the communication wires were sharing a conduit with the 240V power leads and the induced noise was corrupting the handshake signal. I separated the low voltage lines into their own conduit and ran shielded cable for the communication pair. Problem went away immediately. Don't run comm wires next to high voltage unless you have to, and if you do, shield them.
Common wire connections and what they actually do
The power terminals on the outdoor unit are labeled L and N for single phase, or L1, L2, N for three phase. Most residential Aurus units are single phase. The ground terminal goes to the equipment grounding conductor, not the neutral. People mix those up and then wonder why the GFCI trips or the board gets damaged. For the communication interface, the indoor board sends data out on one pair and receives on another. The outdoor board does the reverse. If you cross them, the unit powers up but won't communicate. The compressor and fan won't run. You'll get error codes like E02 or E03 depending on the model year. I've seen techs swap these wires twice before checking the actual diagram. The drain pump connection is separate and usually marked on the indoor PCB. If your Aurus has an integrated condensate pump, it connects to terminals labeled PUMP or DP. These are polarity sensitive on some models so pay attention to the wire color code. Black is typically positive and white is negative on the pump circuit.
Get the Full Details

Remote switch terminals, when present, are simple dry contact inputs. They don't carry line voltage and you can wire a standard wall switch across them. But don't try to pull power through those terminals. I've seen that happen and it burned out the control board relay.
Reading the diagram correctly matters more than memorizing it
The wiring diagram on the inside of the outdoor panel cover is the quick reference. The full schematic in the service manual shows component-level detail. You need both. The cover diagram tells you where wires go. The manual tells you why they go there and what to expect when something fails. One thing the diagrams don't always make clear is that the communication wire gauge and length affect reliability. Aurus specifies a maximum run of about 165 feet for the communication pair on most models. Go beyond that without a signal booster or repeater and you'll get intermittent faults that are a pain to diagnose. The error codes will point at the board but the real issue is signal degradation over distance. Also worth noting: some Aurus models ship with a jumper that bridges certain terminals on the outdoor PCB for single-zone configurations. If you're installing a multi-zone setup, that jumper needs to be removed. The diagram will show you where it is. If you miss it, the extra indoor units won't communicate properly and you'll waste hours chasing wiring faults that aren't actually there.
The download link for the official Aurus Mini Split Wiring Diagram varies by model number. Check the nameplate on your outdoor unit and search the Aurus support site using that exact S/N. Third party diagrams circulate online and they're often for slightly different revisions. Using the wrong one has cost me more than one service call. Get the diagram that matches your serial number range, not just the model family. If you're working on a unit older than three years and the original diagram is hard to find, a lot of technicians keep a library of common Aurus schematics in a folder on their phone. It's not glamorous but it's faster than trying to decode a diagram from a blurry photo someone posted on a forum six years ago. The information density in those old threads is low and the comments are usually contradictory. Bottom line is that the wiring diagram is accurate but only if it matches your specific unit. Verify the model, verify the serial range, and then verify your connections against the actual label on the equipment before you close everything up. Taking fifteen minutes to double check saves about two hours of troubleshooting later.