So You Need a Proper Electric Meter Wiring Diagram
Pulling the wrong wire in a meter base is how you blow a breaker and earn a angry phone call from the utility company. I spent three hours once troubleshooting a meter that registered reverse rotation, only to find the voltage coil leads were crossed between two separate phases. The diagram on the back of the housing didn't match the actual factory internals. That happens more than you think. Most residential wiring diagrams for single-phase meters follow a basic layout, but they're not all identical. Here's the breakdown of what you're actually looking at on a standard 120/240V setup. Terminals on the line side (power coming in):
Terminal 1: Phase A hot from the utility (typically 120V to neutral) Terminal 2: Neutral from the utility Terminal 3: Phase B hot from the utility (the other 120V leg, 180 degrees out of phase from A)
Terminal 4: Ground bond point (not a current-carrying conductor in normal operation) Terminals on the load side (power going to your panel): Terminal 5: Phase A hot output to the main panel
Get the Full Details

Terminal 6: Neutral output to the main panel Terminal 7: Phase B hot output to the main panel Terminal 8: Test port or auxiliary ground reference (depends on manufacturer)
The diagram will show coils inside the meter. The voltage coil connects across Line 1 and Neutral — it's the high-resistance sensing winding that creates the rotating magnetic field. The current coil is in series with the hot conductors. Current flows through it as your home draws power, and the interaction between the two coils drives the register forward. Simple concept, but getting the polarity wrong flips the direction.
Real-World Problems I've Hit
Last year I was upgrading a 1970s-era analog meter to a modern digital one in a duplex setup. The old diagram showed a common neutral bonded at the meter, but the new meter required the neutral to be isolated. I missed that the first time around and connected the service neutral directly to the meter's neutral terminal instead of running it through the load side. The result was the digital meter registering about 40% low because the neutral current wasn't flowing through the current transformer the way it should. The fix was to pull the service neutral from the meter entirely and reroute it to the load panel's neutral bus. Once the neutral stayed out of the meter's current path, the registration went to exactly 100%. This is one of those things that never shows up in the basic diagram — the bonding jumper location changes depending on whether you're doing a meter-tied or panel-tied installation, and the diagram doesn't always clarify that distinction.

Three-Phase Commercial Meters
When you move past residential single-phase, the wiring diagram gets more complex fast. A three-phase four-wire delta or wye system uses different terminal arrangements. Common setups use terminals numbered 1 through 12, sometimes more, depending on the manufacturer. The key terminals are still your phases and neutral, but now you're dealing with multiple current transformers and potential transformers, sometimes external, sometimes internal. I worked on a small commercial building where the engineer specified a high-leg delta meter. The diagram showed standard three-phase connections, but it didn't flag that the high leg — the one with roughly 208V to neutral — had to be identified and kept away from any 120V branch circuits. I found out the hard way when a contractor had wired 120V receptacles off that leg. Three-quarters of his outlets were dead at 208V and would have burned anything plugged into them.
Where the Diagrams Fail You
Here's the honest part: the wiring diagram on most meters is a generic representation. It shows the terminal numbering and the basic coil connections, but it won't tell you about factory-specific quirks like reversed polarity on the current coil, special tap requirements for certain CT ratios, or the fact that some meters require an external jumper between terminals that the diagram marks as unconnected. Utility companies sometimes make field modifications that the diagram doesn't reflect. A meter that was modified for a time-of-use tariff might have a different internal wiring scheme than the baseline diagram shows. If you're relying solely on the sticker diagram, you're flying blind on those units. The workaround is to pull the meter and photograph the actual internal wiring before you disconnect anything. Take a picture of the terminal block, the coil connections, and any jumpers or links that are installed. Then compare it to the diagram. The differences will tell you exactly what's non-standard about that installation.
Download Resources
I keep a folder of the most common Electric Meter Wiring Diagram PDFs from the major manufacturers — Square D, Siemens, Landis+Gyr, and ABB. They cover everything from the basic single-phase residential meters to the three-phase units used in light commercial applications. The diagrams are typically available on the manufacturer websites if you search for the specific model number, but the model numbers on older meters can be worn off or illegible. In those cases, measuring the terminal spacing and identifying the brand by the housing shape gets you close enough to find the right documentation. One more thing that matters: always verify the diagram matches the meter's ampacity rating. A 200-amp meter has different internal conductor sizing and terminal ratings than a 100-amp unit, even if the terminal numbering looks identical on the diagram. Connecting a 200-amp service to a 100-amp rated meter terminal block based purely on the diagram will melt the lugs within months of loading. Check the nameplate before you trust the wiring diagram.