Installing the Honeywell Rth5160d1003: What Actually Happens
The Honeywell RTH5160D1003 is one of those basic five-day programmable thermostats that shows up in a lot of apartments and older homes. It does the job, but it has enough quirks that people either struggle with it or install it wrong the first time. I've replaced enough of these to know where things go sideways. The official manual lives on Honeywell's website. You can find it by searching "RTH5160D1003 manual" or going straight to Honeywell's support page and using their model search. Having it open while you work saves you from guessing on wiring labels and program settings. Don't skip reading the wiring section even if you think you know what you're doing. I've seen people connect the W wire to Y thinking they were being clever, then wonder why the heat came on when the AC kicked in. Start by turning off the power at the breaker. Not the furnace switch, the actual breaker. These things run on 24 volts from your HVAC transformer, and if you don't kill the power first, you risk blowing the fuse on your board or getting a small shock. I once had a job where the previous installer hadn't turned off the breaker, and the thermostat died six months later because someone had crossed two wires while the system was live. Cheap part, expensive callout.
Remove the old thermostat. Take a photo of the wiring first. I mean a real photo with your phone, not a mental note. Wire labels fade, get swapped, or get lost. That photo will save you an hour of troubleshooting later. The RTH5160D1003 uses a standard terminal layout: R for power, C for common, Y for cooling, W for heat, G for fan, and O/B for the heat pump reversal valve if you have one. Simple enough until you get to a system with a supplementary heater or a multi-stage setup, which this thermostat doesn't support anyway. Mount the backplate. Use the level. I know it seems obvious, but crooked thermostats happen way more often than they should, and a crooked plate makes the wiring look different than it actually is when you're trying to match old wires to new terminals. Secure it with the screws provided, then attach your wires. Push the wire ends all the way into the terminal and tighten the screw down firm. A loose wire here causes intermittent heating and cooling that drives everyone crazy, including you. Attach the thermostat body, set the date and time, then configure your program schedule. The RTH5160D1003 lets you program separate times and sleep times for weekdays and weekends, or you can set the same schedule for every day. If you're someone who comes home at different times during the week, stick to weekday/weekend separation rather than trying to make every day identical. It just works better that way.
The Problem No One Warns You About
The C wire situation. This thermostat needs a common wire to power itself consistently. If your old thermostat worked on just two batteries, you probably don't have a C wire connected. The RTH5160D1003 can run on batteries, but it also has a port for a C wire, and when you connect it, the battery life goes from months to essentially permanent. I ran into this exact issue on a job last year where the homeowner had replaced a non-programmable thermostat with this model and was getting low battery warnings every three weeks. Checked the wiring, sure enough, no C wire was connected. Jumpered a 24-volt transformer to the C terminal from the R terminal with a piece of 18-gauge wire, and the problem disappeared. If your system doesn't have a C wire at the thermostat location, you'll need to either run one from the furnace or use a C wire adapter kit. Honeywell sells one, but a lot of HVAC guys just run a short cable from the board. By default, this thermostat comes with fairly generic programming. The heat setpoint defaults to 68 degrees Fahrenheit and the cool setpoint to 78. If you're comfortable with that, leave it. If not, here's what I usually adjust: set the temperature differential to 2 degrees instead of the default. That means the heat kicks on at 66 and turns off at 68, rather than cycling on at 67 and off at 68. Less short-cycling, more even temperatures, and slightly lower energy bills. Another thing people miss is the auto fan setting. If you set the fan to auto, it only runs when the system is actively heating or cooling. Leave it on auto unless you have a specific reason to run the fan continuously. Continuous fan mode pulls air through a dirty filter faster and can actually make your humidity feel higher in the summer because the air isn't getting chilled as effectively. It doesn't support Wi-Fi, smart learning, or two-stage heating and cooling. If you have a heat pump with auxiliary heat, you need to check the manual carefully because the O/B terminal configuration matters, and getting it wrong means your system will reverse between heating and cooling incorrectly. I've seen two instances where someone installed this on a heat pump without reading that section, and the house was freezing in winter because the reversing valve was stuck in cooling mode. The thermostat didn't alarm. It just ran the wrong cycle and nobody noticed for a few weeks. If you have a heat pump, make absolutely sure you understand the O/B switch before you connect anything.
Get the Full Details

It also doesn't have a light sensor or occupancy detection. That's fine for most people, but if you want the thermostat to adjust based on whether anyone's actually home, you're looking at a different product entirely. The RTH5160D1003 is a straightforward programmable thermostat, and it does that job adequately. It's not a smart thermostat disguised as a dumb one, and it's not meant to be.
Final Things to Check Before You Finish
Verify each function individually. Turn the heat on and confirm the W terminal energizes the furnace. Turn the cool on and confirm Y activates the condenser. Set the fan to auto and confirm it stops when the system cycles off. Set it to on and confirm it runs continuously. Test the battery backup by disconnecting power at the breaker and confirming the thermostat holds its program. These five checks take about three minutes and catch about ninety percent of installation errors before they become complaints.