Reading This Book Won't Make You Competent. Here's What Actually Helps.
I picked up Immunodiagnostics A Practical Approach from the Practical Approach Series a few years ago because I was tired of flipping through three different textbooks to figure out why a chemiluminescent immunoassay kept giving me borderline results at 2+ AM. The book is solid. It's not exciting. It's exactly what you'd expect from a Practical Approach volume - dense, reference-heavy, and occasionally frustrating because it assumes you already know half the stuff it's explaining. The book covers the major immunodiagnostics platforms: ELISA, chemiluminescence, fluorescence polarization, nephelometry, turbidimetry, lateral flow assays, and the newer automated immunoassay analyzers you'd find in a clinical lab. Each chapter follows a predictable format - principle, reagents, procedure, quality control, troubleshooting. That predictability is actually a feature. When you're in the lab at 6 PM and a reflex testing protocol is breaking down, you want a chapter that tells you exactly where to look. Here's the thing most people miss about this book. The troubleshooting sections are the best part, but they're also the weakest. The authors will tell you that interferences from heterophile antibodies cause false positives, which is correct but not especially actionable. In practice, heterophile interference isn't a simple yes-or-no problem. It's dose-dependent, analyte-dependent, and highly reagent-specific. I had a case last year where a troponin I assay gave consistently elevated results in a patient with no cardiac symptoms, normal echocardiogram, and normal CK-MB. The book suggests adding blocking agents. That partially worked but didn't solve it. The actual fix was switching to a different antibody pair on another platform - the heterophile reaction was specific to the monoclonal capture antibody used in that particular assay.
Another thing the book doesn't emphasize enough: the difference between analytical sensitivity and clinical sensitivity in immunodiagnostics. You'll see limit of detection values quoted all over the place, but those numbers mean very different things depending on whether they were measured in buffer, in serum, or in the presence of the hook effect. I spent weeks dealing with a growth hormone assay where the manufacturer's quoted LoD was 0.05 µg/L, but in routine patient samples at our lab, the actual precision cutoff at 95% was closer to 0.3 µg/L. The book mentions this concept briefly but doesn't drive home how often published specifications and real-world performance diverge.
Immunodiagnostics A Practical Approach Practical Approach Series
For anyone actually using this as a reference rather than cover-to-cover reading, here's what I'd prioritize. The chapters on quality control and external quality assessment schemes are worth more than the theory sections. The book does a reasonable job explaining Westgard rules in the context of immunoassays, but it doesn't adequately address the specific QC challenges that come with multiplex immunoassays or automated continuous-load analyzers. If your lab runs Elecsys or Architect systems, the general principles apply but the practical details about lot-to-lot verification and instrument-level QC strategies are thin. The section on biotin interference is useful but slightly dated. The book covers the streptavidin-biotin system's role in competitive assays and the false results it can cause, but it predates the widespread clinical recognition of high-dose biotin supplements causing clinically significant interference across multiple platform types. I've seen this now with at least four different analyzer manufacturers, and the workaround isn't always straightforward. For some assays, holding the sample for six hours after biotin administration is sufficient. For others - particularly the streptavidin-based ones at high biotin concentrations - you need to wait significantly longer or dilute the sample. The book doesn't give you that level of practical detail. If you want to actually learn from this book, don't read it passively. Keep it next to the bench. Run through the troubleshooting flowcharts when something goes wrong rather than after. The chapters on assay validation and method comparison are where the book shows its real strength, and those are also the sections most likely to be skipped by people who just want quick answers. Don't skip them. Understanding how to validate a new immunoassay on your platform - the parallelism studies, the recovery experiments, the comparison against a reference method - is what separates someone who operates equipment from someone who actually understands what the equipment is measuring.
Get the Full Details

The book has real limitations. It's not updated frequently enough to keep pace with platform improvements from Roche, Abbott, Siemens, and Architect. Some of the figures and diagrams are from older generation instruments that most labs have phased out. The coverage of emerging technologies like digital ELISA (Single Molecule Array) or proximity extension assays is minimal to nonexistent. If your lab is doing novel immunoassay development or working with cytokine panels using Luminex-type platforms, you'll need supplementary material regardless. For the core clinical immunodiagnostics work - infectious disease serology, tumor markers, hormone assays, autoimmune panels, therapeutic drug monitoring - this book remains one of the more useful single references available. It won't make you an expert. Nothing short of hands-on experience will do that. But it will save you time when the alarm on the analyzer lights up at an inconvenient hour and you need to know whether the problem is in the reagent, the calibrator, the sample, or the instrument itself.