Working with the Sullivan Palatek Service Manual
Most people looking for this manual end up frustrated because it's not something you just download from a modern support page. Sullivan Palatek was absorbed into Mitutoyo decades ago, and their legacy documentation gets scattered across flea markets, estate sales, and the occasional PDF someone uploaded to a forum in 2008. I've spent enough time with their optical comparators and profilometers to know where the real headaches live, and they usually show up before you even open the manual.Sullivan Palatek Service Manual: What You're Actually Looking For
The Sullivan Palatek Service Manual covers calibration procedures, adjustment tolerances, and parts replacement for their line of profile projectors and surfaceprofilers. The most common models people still have running are the SP-1, SP-2, and the P- series optical comparators. Each model has its own manual, and they aren't interchangeable. I once tried to calibrate an SP-2 using an SP-1 document and nearly wrecked the stage leveling screws because the torque specs are completely different. The SP-1 uses a three-point leveling system with 4-40 adjustment screws, while the SP-2 has a four-point air-floating base that requires a fundamentally different approach. Know which machine you're working on before you start reading.The manual itself is usually a thin 40 to 60 page booklet, black and white, printed on cheap paper that disintegrates if you fold it wrong. That's not a metaphor. I've seen original copies where the binding cracked and pages fell out during a basic teardown. Scan it first. Don't be that guy.
Where to Find an Actual Copy
There's no official Sullivan Palatek site anymore. The closest thing to a legitimate source is the Mitutoyo archival materials, but they don't publish these freely. Your realistic options are: - eBay and Mercari. People sell originals or photocopied scans. Expect to pay $20 to $80 depending on condition. A clear photocopy of all pages is often better than a torn original. - Online forums. Machines Plus Tools, PDHforum, and the MyMill group sometimes have members who upload PDFs. Search by model number, not just "Sullivan Palatek." - Wayback Machine. Someone uploaded a decent scan of the SP-1 manual a few years back. It's not guaranteed to be there now, but it's worth checking archive.org with the model number as your query. I found my copy of the SP-2 service manual on a used equipment listing that also included a broken magnification indicator. I ignored the broken part, grabbed the manual, and later sold the projector for parts to cover the cost. Happens all the time.How to Actually Use It
The first thing the manual will tell you to do is level the stage. That sounds straightforward until you realize the bubble level on these machines is mounted on the stage casting itself, not on a reference surface. If the casting has any wear from years of parts being slid around, your level reading will lie to you. The workaround I use is to bring a precision machinist level onto the stage and cross-check. The Sullivan original level is accurate enough when new, but after twenty years of shop vibrations and temperature swings, it drifts.When you get to the magnification calibration section, the manual assumes you have a calibrated reticle and a master grind gauge. Most people don't. What actually works is using a precision glass scale—Mitutoyo makes replacements that fit—and verifying the magnification at two points across the field of view. The manual only describes checking at center. That's where beginners miss field curvature errors. If your edge measurements are off by more than 0.0002 inches, your projector needs optical realignment, not just a stage adjustment. The manual glosses over that. It has a section on adjusting the condenser lens, but it doesn't explain the sequence. I learned it the hard way by loosening the wrong screw first and losing focus on three of four field positions.
The Adjustment Sequence Nobody Warns You About
Here's what the manual doesn't make obvious: the illumination system and the projection optics are coupled. When you change bulbs or reseat the lamp housing, you have toalign the Köhler illumination before anything else. If you skip that and go straight to stage calibration, every measurement you take afterward will have a consistent error because the light path is misregistered. I've seen techs spend hours chasing stage errors that turned out to be a bulb that was half a millimeter out of position.The sequence is: lamp alignment, condenser centering, field diaphragme adjustment, then aperture diaphragme, and finally stage calibration. The manual presents these as separate procedures. They're not separate. They're a chain. Fix one link and the others shift slightly.
Get the Full Details

Common Pitfalls and Where the Manual Falls Short
The biggest gap in the Sullivan Palatek Service Manual is the treatment of the rotary stage. On the SP-2, the rotary table has a indexing plate with 360 marked positions, but the actual mechanical indexing has a cumulative error that the manual doesn't quantify. I measured mine and found up to 0.03 degrees of play between adjacent positions depending on which direction you approached from. If you're doing angular measurements and you always approach from the same direction, it's fine. If you jump around the dial, you'll accumulate error. The fix is to always rotate clockwise into position and never cross the zero mark without recalibrating. The manual doesn't say that. You learn it from burning through a job and wondering why your angles were wrong.Another thing: the replacement parts list in the manual is incomplete. Sullivan stopped producing their own parts when Mitutoyo took over, so many of the items listed out of stock are now replaced by Mitutoyo equivalents with slightly different dimensions. The stage dovetails on an SP-1, for example, are 0.0003 inches tighter on the Mitutoyo replacement. It works, but you'll need to hand-fit the bushings. Grab a set of precision shims before you order anything from the parts list.
What This Manual Can't Fix
Be honest about what the Sullivan Palatek Service Manual can and can't do for you. It will get you through a standard calibration cycle. It won't help you diagnose a projector that's producing fuzzy images across the entire field, because that's usually a worn objective lens or a cracked mirror in the light path, and the manual doesn't cover optical component refurbishment. It also won't help with electronic upgrades. These machines are all analog. If you want digital readouts or CNC stage control, you're looking at a custom fabrication project, and no vintage service manual is going to cover that.For the core tasks—leveling, magnification verification, stage travel calibration, and basic maintenance—the Sullivan Palatek Service Manual is adequate. Just treat it as a starting point, not a complete guide. Cross-reference with whatever manufacturer documentation you can find for the specific model, and keep a machinist level and a glass scale on hand. Everything else you'll figure out after you've fought with the machine enough times.