Setting Up a Utilitech Remote Control Outlet
I bought three of these off Amazon because the price was right and I needed something simple for a floor lamp and a space heater. They work. They also don't work the way the manual implies they will. The manual is thin enough to barely qualify as paper. Start by unpacking and laying everything out. You get the outlet module itself, a small handheld remote, and usually a screwdriver if you bought the newer version. The outlet plugs into any standard 120V wall receptacle in your home. That's it for the hardware side. The remote pairs during initial setup. Here is what the instructions leave out. The pairing process only works reliably when the outlet is within three feet of the remote on first use. After that, range jumps to about twenty-five feet line of sight, but throw a drywall corner or a metal stud wall in between and you are down to ten feet or less. I learned that standing in my kitchen trying to pair a unit that was six feet away across the island while a dishwasher ran nearby.
To pair it yourself, plug the outlet into the wall and wait until the indicator LED blinks slowly. That blink means it is in learning mode. Press and hold the ON button on the remote for about three seconds. The LED on the outlet should flash rapidly once it locks onto the code, then go solid. If it keeps blinking after ten seconds without flashing rapidly, the remote did not pair. Unplug the outlet, wait five seconds, plug it back in, and try again. This reset step fixes the vast majority of pairing failures. I have done this at least a dozen times over two years and it still works. The remote uses a fixed code system, not rolling code. That means if you pair it near a neighbor's identical receiver module, you can accidentally share the same frequency. I walked outside to test range one evening and realized the remote was toggling a lamp in the house next door that was plugged into a matching outlet. I solved it by pressing the LOCK button on the remote after pairing, which locks the code to that single outlet. Not every batch includes that button, but the newer ones do. Check your remote before you assume the unit is defective. Power rating matters more than people admit. These outlets are rated for 10 amps resistive load at 120 volts, which is 1200 watts. A space heater pulling 1500 watts will trip the internal breaker or degrade the contacts over time. I ran a 1500-watt heater through one for about six weeks before the remote started becoming intermittent on the OFF command. The outlet still turned on, but the remote relay was sticking. Replace it before it becomes a fire hazard. Do not use these for anything over 1200 watts, and I would actually recommend staying under 1000 watts if you want the unit to last more than a year.
If you want to control multiple outlets with one remote, you can pair up to four outlets. The trick is that the remote cycles through channels with a short press. Channel 1 controls the first paired outlet, Channel 2 the second, and so on. Long press turns all channels on or off. Some users miss this entirely and end up buying a second remote when they only needed to learn the channel switch sequence, which is pressing and holding the CH button until the LED blinks, then pressing ON to assign that outlet to the next channel. Interference is a real problem in apartment buildings. I live in a duplex with shared walls and three other families using the same brand of outlet. At first I thought my remote was failing because it would respond inconsistently. The issue was code collision across units. These remotes use simple 4-bit dip switches inside the battery compartment, not modern encryption. There are only sixteen possible codes. I opened the remote, flipped the dip switch to position 16, and the cross-control stopped immediately. You need to do the same on every outlet you want to keep isolated. Battery replacement is straightforward but easily done wrong. The remote takes a CR2032 coin cell. I used a CR2032 that was two years old from a drawer and wondered why the range dropped to eight feet. New battery fixed it. Do not cheap out on the coin cell. A fresh name-brand CR2032 costs about eighty cents and restores full range.
Get the Full Details

One thing the manual never mentions is that these outlets draw about 0.5 watts in standby even when the load is off. That is negligible on its own, but if you have five of them scattered around the house, you are looking at roughly 2.5 watts idle draw, or about twenty-two kilowatt-hours per year. Not worth worrying about, but worth knowing if you are calculating phantom load for an efficiency project. If you need something for heavy appliances or outdoor use, these are not the right tool. They are indoor-only, not weather rated, and not designed for motorized loads like compressors or well pumps. For those applications, look at a proper smart switch rated for the load type. These outlets are fine for lamps, fans, holiday decorations, and low-draw appliances. They just require you to respect the limits and set the dip switches correctly before you plug anything in.