condensing unit wiring diagram: Understanding Electricity and Wiring Diagrams for HVAC/R Robert Chatenever, 2000 This book provides HVAC/R service technicians with exceptionally practical information on the unique wiring diagrams, methods, technician short-cuts, and potential pitfalls encountered on the job. It begins with a discussion of general electricity and electrical circuits, and then moves quickly into explaining wiring diagrams for HVAC and refrigeration systems, and the new devices that are encountered with each new diagram. It features accessible, technician-level explanations of electronics. Electrical Concepts. Simple Currents. Standing Pilot Furnaces. Heating/Air Conditioning Circuits. Troubleshooting Strategies. Testing and Replacing Common Devices. Repair Strategies. Commercial Systems. Motor Applications. Power Wiring. Testing and Replacing Motors and Start Relays. How Motors Work. Low-Voltage Room Thermostats. Electronic Ignition Gas-Fired Furnaces. Oil Heat. Electric Heat. Boilers. Heat Pump. Ice Makers. Miscellaneous Devices and Accessories. Wiring Techniques. DDC Controllers. For HVAC/R service technicians. |
condensing unit wiring diagram: Refrigeration Engineering , 1937 English abstracts from Kholodil'naia tekhnika. |
condensing unit wiring diagram: Electricity, Electronics, and Wiring Diagrams for HVACR Edward Mahoney, 2014 For all courses in electricity, electronics and wiring for HVACR; and for Principles of HVACR courses. Electricity, Electronics and Wiring Diagrams for HVACR is a complete, simple, and up-to-date guide to the essentials of electricity and electronics for technicians working in today's HVACR field. Part I gives students a firm foundation in the electrical and electronics concepts utilized in HVACR. Then, using these concepts, Part II presents a wide variety of practical circuits and systems, addressing the challenges HVACR technicians are likely to encounter most often. Building on the diagrams and solutions provided here, students will be able to address even the most complex circuits and problems they will encounter in the field. New topics in this edition include Kirchoff's Law, Vector Analysis of AC Circuits, high-efficiency ECM motors, and remote control thermostats. Designed for simplicity, this text presents clear objectives, easy-to-understand explanations, and well-focused review questions. |
condensing unit wiring diagram: , |
condensing unit wiring diagram: Practical Controls Steven R. Calabrese, 2020-11-26 Geared toward the HVAC professional, Practical Controls: A Guide to Mechanical Systems provides a solid foundation and well-rounded understanding of the role of controls in mechanical systems design and installation. This book takes a concise look at HVAC controls and controls methods - including electrical, electronic, and microprocessor-based controls and control systems. Using real world examples, it explores how various mechanical systems installed in today's facilities are best controlled. The text is a practical resource to controls contracting, providing basic rules, equipment guidelines, rules of thumb, pros and cons, and do's and don'ts. |
condensing unit wiring diagram: Air Conditioning Service Guide 2nd Edition Michael Prokup, 2021-09-01 Now in its Second Edition, this training manual was written by industry renowned presenter and author, Michael Prokup. This e-book is a comprehensive reference for servicing R-22/R-410A residential split air conditioning systems and is a must have for every student and service technician! Step-by-step service procedures and quick reference diagrams will help guide technicians through troubleshooting and service. 168 pages and fully illustrated. Copyright 2022 Topics covered include: Mechanical Refrigeration Cycle Basics Refrigerants and Oils Superheat Subcooling and Condensers Refrigerant Piping Charging Diagnosing Refrigeration Circuit Problems High Voltage Circuit Compressors ECM Blower Motors PSC Motors Air Volume |
condensing unit wiring diagram: Technical Monograph Tennessee Valley Authority, 1940 |
condensing unit wiring diagram: Manuals Combined: 150+ U.S. Army Navy Air Force Marine Corps Generator Engine MEP APU Operator, Repair And Parts Manuals , Over 36,000 total pages .... Just a SAMPLE of the CONTENTS by File Number and TM Number:: 013511 TM 5-6115-323-24P 4 GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 1.5 K SINGLE PHASE, AC, 120/240 V, 28 VDC (LESS ENGINE) DOD MODELS MEP-015A, 60 HZ (NSN 6115-00-889-1446) AND (DOD MODEL MEP-025A) 28 VDC (6115-00-017-8236) {TO 35C2-3-385-4; SL 4-07609A/07610A} 013519 TM 5-6115-329-25P 1 GENERATOR SET, GASOLINE ENGINE DR (LESS ENGINE) 0.5 KW, AC, 120/240 V, 60 HZ, 1 PHASE (DOD MODEL (FSN 6115-923-4469); 400 HZ (MODEL MEP-019A) (6115-940-7862) AN DC (MODEL MEP-024A) (6115-940-7867) {TO 35C2-3-440-14} 013537 TM 5-6115-457-12 7 GENERATOR SET, ENGINE DRIVEN, TACTICAL, SKID MTD; 100 KW, 3 PHASE, 4 WIRE, 120 240/416 V (DOD MODELS MEP-007A), UTILITY CLASS, 50/60 HZ (NSN 6115-00-133-9101), (MODEL MEP-106A) PRECISE CLASS, 50/60 H (6115-00-133-9102), (MODEL MEP-116A) PRECISE CLASS, 400 KW (6115-00-133-9103) INCLUDING OPTIONAL KITS (MODEL MEP-007 AWF) WINTERIZATION KIT, FUEL BURNING (6115-00-463-9082), (MEP-007AWE WINTERIZATION KIT, ELECTRIC (6115-00-463-9084), (MODEL MEP-007A DUMMY LOAD KIT (6115-00-463-9086) AND (MODEL MEP-007AWM) WHEEL 013538 TM 5-6115-457-34 12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID 100 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 V (DOD MODELS MEP0 UTILITY CLASS, 50/60 HZ (NSN 6115-00-133-9101); (MODEL MEP106A) CLASS, 50/60 HZ (6115-00-133-9102) AND (MODEL MEP116A), PRECISE 400 HZ (6115-00-133-9103); INCLUDING OPTIONAL KITS (DOD MODELS MEP007AWF) WINTERIZATION KIT, FUEL BURNING (6115-00-463-9082); MEP007AWE) WINTERIZATION KIT, ELECTRIC (6115-00-463-9084); (MOD MEP007ALM) DUMMY LOAD KIT (6115-00-463-9086) AND (MODEL MEP007A MOUNTING KIT (6 013540 TM 5-6115-458-24P 9 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL, SKID MTD., 2 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS, DOD MODELS MEP009A UTILITY CLASS, 50/60 HZ (NSN 6115-00-133-9104) AND MODEL MEP108A PRECISE CLASS, 50/60 HZ (6115-00-935-8729) INCLUDING OPTIONAL K DOD MODELS MEP009AWF, WINTERIZATION KIT, FUEL BURNING (6115-00-403-3761), MODEL MEP009AWE, WINTERIZATION KIT, ELECTRIC (6115-00-489-7285) 013545 TM 5-6115-465-12 19 GENERATOR DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 30 KW, 3 PHASE, 4 WIRE 120/208 AND 240/416 V (DOD MODEL MEP-005A), UTILITY CLASS, 50/6 (NSN 6115-00-118-1240), (MODEL MEP-104A), PRECISE CLASS, 50/60 (6115-00-118-1247), (MODEL MEP-114A), PRECISE CLASS, 400 HZ (6115-00-118-1248) INCLUDING AUXILIARY EQUIPMENT (DOD MODEL MEP WINTERIZATION KIT, FUEL BURNING (6115-00-463-9083), (MODEL MEP- WINTERIZATION KIT, ELECTRIC (6115-00-463-9085), (MODEL MEP-005A LOAD BANK KIT (6115-00-463-9088) AND (MODEL MEP-005AWM), WH 013547 TM 5-6115-465-34 12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTIC SKID MTD, 30 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 V (DOD MO MEP-005A), UTILITY, 50/60 HZ (NSN 6115-00-118-1240), (MODEL MEP-104A), PRECISE, 50/60 HZ (6115-00-118-1247), (MODEL MEP-114 PRECISE, 50/60 HZ (6115-00-118-1248) INCLUDING OPTIONAL KITS (MODEL MEP-005AWF) WINTERIZATION KIT, FUEL BURNING (6115-00-463 (MODEL MEP-005AWE) WINTERIZATION KIT, ELECTRIC (6115-00-463-908 (MODEL MEP-005ALM) LOAD BANK KIT (6115-00-463-9088) (MODEL MEP- WHEEL MOUNTING KIT (6115-00 013548 TM 5-6115-545-12 18 GENERATOR DIESEL ENGINE DRIVEN, TACTICAL SKID MTD., 60 KW, 3 PHASE, 4 WIR 120/208 AND 240/416 VOLTS, DOD MODEL MEP-006A, UTILITY CLASS, 5 (NSN 6115-00-118-1243) DOD MODEL MEP-105A, PRECISE CLASS, 50/60 (6115-00-118-1252) DOD MODEL MEP-115A, PRECISE CLASS, 400 HZ (6115-00-118-1253) INCLUDING OPTIONAL KITS, DOD MODEL MEP006AWF WINTERIZATION KIT, FUEL BURNING (6115-00-407-8314) DOD MODEL MEP006AWE, WINTERIZATION KIT, ELECTRIC (6115-00-455-7693) DOD M MEP006ALM, LOAD BANK KIT (6115-00-407-8322) DOD MODEL MEP006 013550 TM 5-6115-545-34 12 INTERMEDIATE (FIELD) (DIRECT AND GENERAL SUPPORT) AND DEPOT MAINTENANCE MANUAL FOR GENERATOR SET, DIESEL ENGINE DRIVEN, TAC SKID MTD., 60 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS DOD MODELS MEP-006A, UTILITY CLASS, 50/60 HZ (FSN 6115-118-1243 MEP-105A, PRECISE CLASS, 50/60 HZ (6115-118-1252) AND MEP-115A, PRECISE CLASS, 400 HZ (6115-118-1253) {TO 35C2-3-444-2; NAVFAC P-8-626-34; TM 00038G-35} 015378 TM 5-6115-323-14 10 GENERATOR GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 1.5 KW, SI PHASE, AC, 120/240 V, 28 V, DC (LESS ENGINE) (DOD MODELS MEP-01 60 HZ (NSN 6115-00-889-1446) AND (MODEL MEP-025A) 28 V DC (6115-00-017-8236) {TO 35C2-3-385-1} 015380 TM 5-6115-332-24P 3 GENERATOR GASOLINE ENGINE: AIR COOLED, 5 KW, AC, 120/240 V, SINGLE PHASE; 120/208 V, 3 PHASE, SKID MOUNTED, TUBULAR FRAME (LESS ENGINE) M DESIGN: 60 HZ (DOD MODEL MEP-017A) (NSN 6115-00-017-8240); 400 (DOD MODEL MEP-022A) (6115-00-017-8241) {TO 35C2-3-424-24} 020611 LO 5-6115-457-12 GENERATOR SET, DIESEL ENGINE DRIVEN; SKID MTD, 100 KW, 3 PHASE, 120/208 AND 240/416 V (DOD MODELS MEP-007A), UTILITY CLASS, 50/ (NSN 6115-00-133-9101); (MODEL MEP-106A) PRECISE CLASS, 50/60 H (6115-00-133-9102) AND (MODEL MEP-116A), PRECISE CLASS, 400 HZ (6115-00-133-9103) 020612 LO 5-6115-458-12 GENERATOR SET, DIESEL ENGINE DRIVEN, SKID MTD, 200 KW, 3 PHASE, 4 WIRE, 120/208/416 VOLTS, DOD MODELS MEP-009A, UTILITY CLASS, 50/60 HERTZ (NSN 6115-00-133-9104), MEP-108A, PRECISE CLASS, 50 HERTZ (6115-00-935-8729) {LO 07536A-12} 020614 LO 5-6115-465-12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL, SKID MOUNTED, 30 3 PHASE, 4 WIRE, 120/206 AND 240/416 V (DOD MODEL MEP-055A), UT CLASS, 50/60 HZ (NSN 6115-00-118-1240); (MODEL MEP 104A), PRECI CLASS, 50/60 HZ (6115-00-118-1247) AND (MODEL 114A) PRECISE CLA 400 HZ (6115-00-118-1248) 025150 TM 5-6115-271-14 12 GENERATOR SET, GASOLINE ENGINE DRIVEN, S MTD, TUBULAR FRAME, 3 KW, 3 PHASE, AC, 120/208 AND 120/240 V, 2 DC (LESS ENGINE) DOD MODEL MEP-016A, 60 HZ (NSN 6115-00-017-823 MODEL MEP-016C 60 HZ (6115-00-143-3311) MODEL MEP-021A 400 HZ (6115-00-017-8238) MODEL MEP-021C 400 HZ (6115-01-175-7321) MODEL MEP-026A DC HZ (6115-00-017-8239) MODEL MEP-026C 28 V DC (6115-01-175-7320) {TO 35C2-3-386-1; TM 05926A-14; NAVFAC P-8-6 025151 TM 5-6115-271-24P 3 GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULA FRAME, 3 KW, 3 PHASE, AC; 120/208 AND 120/240 VOLTS, 28 VDC (LE ENGINE) (DOD MODEL MEP-016A) 60 HERTZ (NSN 6115-00-017-8237) (MEP-021A) 400 HERTZ (6115-00-017-8238) (MEP-026A) 28 VDC HERTZ (6115-00-017-8239) (MEP-016C) 60 HERTZ (6115-01-143-3311) (MEP- 400 HERTZ (6115-01-175-7321) (MEP-026C) 28 VDC HERTZ (6115-01-175-7320) {TO 35C2-3-386-4; SL-4-05926A} 032507 TM 5-6115-275-14 10 GENERATOR SET, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 10 KW, AC, 120/208V PHASE, AND 120/240V, SINGLE PHASE, LESS ENGINE: DOD MODELS MEP- HZ, (NSN 6115-00-889-1447) AND MEP-023A, 400 HZ (6115-00-926-08 {NAVFAC P-8-615-14; TO 35C2-3-452-1} (THIS ITEM IS INCLUDED ON EM 0086, EM 0088 & EM 0127) 032508 TM 5-6115-275-24P 5 GENERATOR, GASOLINE ENGINE DRIVEN, SKID MOUNTED, TUBULAR FRAME, 10 KW, AC, 120/208 V, 3 PHASE AND 120/240 V, SINGLE PHASE (LESS ENGINE); D MEP-018A, UTILITY CLASS, 60 HZ (NSN 6115-00-889-1447) AND MEP-0 PRECISE CLASS, 400 HZ (6115-00-926-0843) {NAVFAC P8-615-24P; TO 35C2-3-452-4} (THIS ITEM IS INCLUDED ON EM 0086, EM 0088 & EM 0127) 032551 TM 5-6115-584-12 11 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 5 KW, 1 PHASE, 2 WIRE; 1 PHASE, 3 WIRE; 3 PHASE, 4 WIRE, 120, 120/240 AND 120/208 V (DOD MODEL MEP-002A) UTILITY CLASS, 60 HZ (NSN 6115-00-465-1044) {NAVFAC P-8-622-12; TO 35C2-3-456-1; TM 05682C-12} 032640 TM 5-6115-585-12 12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 10 KW, 1 PHASE, 2 WIRE 1 PHASE, 3 WIRE AND 3 PHASE, 4 WIRE; 120, 120/240 AND 120/208 V (DOD MODEL MEP-003A) UTILITY CLASS, 60 HZ (NSN 6115-00-465-1030 AND (MODEL MEP-112A), UTILITY CLASS, 400 HZ (6115-00-465-1027) {NAVFAC P-8-623-12; TO 35C2-3-455-1; TM-05684C/05685B-12} 032781 TM 5-6115-584-34 8 GENERATOR SET, DIESEL ENGINE DRIVEN, TAC SKID MOUNTED, 5 KW, 1 PHASE, 2 WIRE, 1 PHASE, 3 WIRE, 3 PHASE, 120, 120/240 AND 120/208 V (DOD MODEL MEP-002A), UTILITY CLASS, (NSN 6115-00-465-1044) {NAVFAC P-8-622-34; TO 35C2-3-456-2; TM 0568C-34} 032936 TM 5-6115-329-14 4 GENERATOR SET GASOLINE ENGINE DRIVEN, 0.5 KW (LESS ENGINE) (DOD MODEL MEP-014 UTILITY CLASS, 60 HZ) (NSN 6115-00-923-4469), (DOD MODEL MEP-01 UTILITY CLASS, 400 HZ (6115-00-940-7862) AND (DOD MODEL MEP-024 UTILITY CLASS, 28 VDC (6115-00-940-7867) {TO 35C2-3-440-1} 033374 TM 5-6115-332-14 10 GENERATOR SET, TAC GASOLINE ENGINE: AIR COOLED, 5 KW, AC, 120/240 V, SINGLE PHASE, V, 3 PHASE, SKID MOUNTED, TUBULAR FRAME (LESS ENGINE) (MILITARY DOD MODEL MEP-017A), UTILITY, 60 HZ (NSN 6115-00-017-8240) AND MODEL MEP-022A), UTILITY, 400 HZ (6115-00-017-8241) {NAVFAC P-8-614-14; TO 35C2-3-424-1} 033750 TM 5-6115-585-34 9 GENERATOR SET, DIESEL ENGINE DRIVEN, TAC SKID MOUNTED, 10 KW, 1 PHASE, 2 WIRE, 1 PHASE, 3 WIRE, 3 PHASE, 4 WIRE, 120, 120/240 AND 120/208 VOLTS (DOD MODEL MEP-003A), UT CLASS, 60 HZ (NSN 6115-00-465-1030) {NAVFAC P-8-623-12; TO 35C2-3-455-2; TM-05684C/05685B-34} 034072 TM 5-6115-585-24P 5 GENERATOR SET, DIESEL ENGINE DRIVEN, TA SKID MTD, 10 KW, 1 PHASE, 2 WIRE; 1 PHASE, 3 WIRE; 3 PHASE, 4 W 120, 120/240 AND 120/208 V (DOD MODELS 003A), UTILITY CLASS, 60 (NSN 6115-00-465-1030) AND (MODEL MEP-112A), UTILITY CLASS, 400 (6115-00-465-1027) {NAVFAC P-8-623-24P; TO 35C2-3-455-4; SL-4-05684C/06585B} 040180 TM 5-6115-584-12-HR HAND RECEIPT MANUAL COVERING END ITEM/COMPONENTS OF END ITEM (C BASIC ISSUE ITEMS (BII), AND ADDITIONAL AUTHORIZATION LIST (AAL GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 5 KW, 1 WIRE; 1 PH, 3 WIRE; 3 PH, 4 WIRE, 120, 120/240 AND 120/208 V (D MEP-002A) UTILITY CLASS, 60 HZ (NSN 6115-00-465-1044) 040833 TM 5-6115-458-12-HR HAND RECEIPT MANUAL COVERING THE END ITEM/COMPONENTS OF END ITE BASIC ISSUE ITEMS (BII), AND ADDITIONAL AUTHORIZATION LIST (AA GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL, SKID MOUNTED, 20 3 PHASE, 4 WIRE, 120/208 AND 240/416 V (DOD MODEL MEP-009A), UT CLASS, 50/60 HZ (NSN 6115-00-133-9104) AND (DOD MODEL MEP-108A) PRECISE CLASS, 50/60 HZ (6115-00-935-8729) 040843 TM 5-6115-593-34 GENERATOR SET, DIESEL ENGINE DRIVEN, TAC SKID MTD, 500 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS DOD MODEL, MEP-029A, CLASS UTILITY, 50/60 HZ, (NSN 6115-01-030- DOD MODEL, MEP-029B, CLASS UTILITY, 50/60 HZ, (6115-01-318-6302 INCLUDING OPTIONAL KITS DOD MODEL, MEP-029AHK, HOUSING KIT, (6115-01-070-7550), DOD MODEL, MEP-029ACM, AUTOMATIC CONTROL MO (6115-01-275-7912) DOD MODEL, MEP-029ARC, REMOTE CONTROL MODULE (6110-01-070-7553) DOD MODEL, MEP-029ACC, REMOTE CONTROL CABLE, (6110-01-087-4127) {NAVFAC P-8 041070 TM 5-6115-593-12 GENERATOR SET, ENGINE DRIVEN, TACTICAL SKID MTD, 500 KW, 3 PHASE, 4 WIRE; 120/ 240/416 VOLTS DOD MODEL MEP-029A; CLASS UTILITY, HERTZ 50/60; (NSN 6115-01-030-6085); MEP-029B; UTILITY; 50/60; (6115-01-318- INCLUDING OPTIONAL KTS DOD MODELS MEP-029AHK; NOMENCLATURE HOUS (6115-01-070-7550) MEP-029ACM; AUTOMATIC CONTROL MODULE; (6115-01-275-7912); MEP-029ARC, REMOTE CONTROL MODULE, (6110-01-070-7553); MEP-029ACC, REMOTE CONTROL CABLE (6110-01-087-4127) {TO 35C2-3-463-1} 041338 LO 55-1730-229-12 POWER UNIT, AVIATION, MULTI-OUTPUT GTED ELECTRICAL, HYDRAULIC, PNEUMATIC (AGPU), WHEEL MOUNTED, SELF-PROPELLED, TOWABLE DOD MODEL-MEP-360A, CLASS-PRECISE, HERTZ-400, (NSN 1730-01-144-1897 042791 TM 5-6115-457-12-HR HAND RECEIPT MANUAL COVERING THE BASIC ISSUE ITEMS (BII) FOR GE SET, DIESEL ENGINE DRIVEN, TACTICAL, SKID MTD; 100 KW, 3 PHASE, 120/208 AND 240/416 V (DOD MODELS MEP007A), UTILITY CLASS, 50/6 (NSN 6115-00-133-9101), (MODEL MEP-106A), PRECISE CLASS, 50/60 (6115-00-133-9102) AND (MODEL MEP116A) PRECISE CLASS, 400 HZ (6115-00-133-9103) 043437 TM 5-6115-593-24P 1 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MOUNTED, 500 KW, 3 PHA 4 WIRE; 120/208 AND 240/416 VOLTS DOD MODEL MEP-029A UTILITY CL 50/60 HZ (NSN 6115-01-030-6085) MEP-029B UTILITY CLASS, 50/60 (6115-01-318-6302) INCLUDING OPTIONAL KITS DOD MODEL MEP-029AHK HOUSING KIT (6115-01-070-7550) MEP-029ACM AUTOMATIC CONTROL MOD (6115-01-275-7912) MEP-029ARC REMOTE CONTROL MODULE (6110-01-070-7553) MEP-029ACC REMOTE CONTROL CABLE (6110-01-087 {NAVFAC P-8-631-24P; TO 35C2-3-463-4} 044703 TM 5-6115-545-12-HR HAND RECEIPT MANUAL COVERING COMPONENTS OF END ITEM (COEI), BAS ITEMS (BII), AND ADDITIONAL AUTHORIZATION LIST (AAL) FOR GENERA DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 60 KW, 3 PHASE, 4 WIRE 120/208 AND 240/416 V (DOD MODELS MEP-006A) UTILITY CLASS, 50/6 (NSN 6115-00-118-1243), (MODEL MEP-105A) PRECISE CLASS, 50/60 H (6115-00-118-1252) AND (MODEL MEP-115A) PRECISE CLASS, 400 HZ (6115-00-118-1253) 050998 TM 5-6115-600-12 8 GENERATOR DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 100 KW, 3 PHASE, 4 WIR 120/208 AND 240/416 V (DOD MODEL MEP-007B) CLASS UTILITY, 50/60 (NSN 6115-01-036-6374) INCLUDING OPTIONAL KITS, DOD MODEL MEP00 WINTERIZATION KIT, FUEL BURNING AND MEP007BWE WINTERIZATION KIT ELECTRIC 051007 TM 5-6115-600-24P 4 GENERATOR SET, DIESEL ENGINE DRIVEN, 100 KW, 3 PHASE, 4 WIRE, 120/208 AND VOLTS (DOD MODEL MEP-007B), UTILITY CLASS, 50/60 HZ (NSN 6115-01-036-6374) INCLUDING OPTIONAL KITS, DOD MODEL MEP007BWF, WINTERIZATION KIT, FUEL BURNING AND MEP007BWE WINTERIZATION KIT, ELECTRIC {TO 35C2-3-442-14; NAVFAC P-8-628-24P; SL-4-07464B} 057268 LO 5-6115-600-12 GENERATOR SET, DIESEL ENGINE DRIVEN; TACTICAL, SKID MTD, 100 KW PHASE, 4 WIRE; 120/208 AND 240/416 V (DOD MODEL MEP007B), CLASS UTILITY, 50/60 HZ (NSN 6115-01-036-6374) 057513 LO 5-6115-604-12 GENERATOR SET, DIESEL ENGINE DRIVEN, AIR TRANSPORTABLE; SKID MT 750 KW, 3 PHASE, 4 WIRE; 2400/4160 AND 2200/3800 VOLTS (DOD MOD MEP208A) CLASS PRIME UTILITY, HZ 50/60 (NSN 6115-00-450-5881) {LI 6115-12/9} 060183 TM 5-6115-612-24P 6 GENERATOR SET, AVIATION, GAS TURBINE ENGINE DRIVEN, INTEGRA TRAILER MOUNTED, 10KW, 28 VOLTS MODEL MEP-362A, PRECISE, DC (NSN 6115-01-161-3992) {TM 6115-24P/1; AG-320B0-IPE-000; TO 35C2-3-471-4} 060188 TM 5-6115-612-34 4 GENERATOR SET, AVIATION, GAS TURBINE ENG DRIVEN, INTEGRAL TRAILER MOUNTED 10KW 28 VOLTS DOD MODEL MEP 36 PRECISE, DC, (NSN 6115-01-161-3992) {AG-320BO-MME-OOO; TM 6115- TO 35C2-3-471-2} 060645 LO 5-6115-612-12 AVIATION GENERATOR SET, GAS TURBINE, ENGINE DRIVEN, INTEGRAL TR MOUNTED, 10KW, 28 VOLTS DC DOD MODEL MEP 362A CLASS PRECISE (NSN 6115-01-161-3992) 060921 TM 55-1730-229-34 5 POWER UNIT, AVIATION, MULTI-OUTPUT GTED, ELECTRICAL, HYDRAULIC, PNEUMATIC (AGPU) WHEEL MOUNTED, SELF-PROPELLED, TOWA AC 400HZ, 3PH, 0.8 PF, 115/200V, 30 KW, DC 28VDC 700 AMPS, PNEUMATIC, 60 LBS/MIN. AT 40 PSIG, HYDRAULIC, 15 GPM AT 3300 PS DOD MODEL MEP-360A, CLASS PRECISE, 400 HERTZ, (NSN 1730-01-144- {AG 320A0-MME-000; TO 35C2-3-473-2; TM 1730-34/1} 060922 TM 55-1730-229-12 8 POWER UNIT, AVIATION, MULTI-OUTPUT GTED ELECTRICAL, HYDRAULIC, PNEUMATIC (AGPU) WHEEL MOUNTED, SELF-PROPELLED, TOWABLE, AC 400HZ, 3PH, 0.8 PF, 115/200V, 30 KW, DC 28 VDC 700 AMPS, PNEUMATIC 60 LBS/M AT 40 PSIG, HYDRAULIC 15 GPM AT 3300 PSIG, DOD MODEL MEP-360A, CLASS PRECISE, HERTZ 400, (NSN 1730-01-144-1897) {AG 320A0-OMM-OOO; TO 35C2-3-473-1; TM 1730-12/1} 061758 LO 5-6115-614-12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD. 200 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS MODEL MEP009B, UTILI 50/60 HERTZ, (NSN 6115-01-021-4096) 061772 LO 5-6115-622-12 GENERATOR SET, DIESEL ENGINE-DRIVEN, WHEEL MOUNTED 750-KW, 3-PH 4-WIRE, 2200/3800 AND 2400/4160 VOLTS CUMMINS ENGINE COMPANY IN MODEL KTA-2300G-2 DOD MODEL MEP-012A; CLASS UTILITY; HERTZ 062762 LO 5-6115-615-12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MOUNTED, 3 K MODEL 016B; CLASS UTILITY MODE 50/60 HZ (NSN 6115-01-150-4140); DOD MODEL MEP-021B; CLASS UTILITY; MODE 400 HZ (6115-01-151-812 DOD MODEL MEP-026B; CLASS UTILITY; MODE 28 VDC (6115-01-150-036 {LI 05926B/06509B-12/5; P-8-646-LO} 064310 TM 5-6115-626-14&P 2 POWER UNIT PU-406B/M (NSN 6115-00-394-9576) MEP-005A 30 KW 60 HZ GENERATOR SET M200A1 2-WHEEL4-TIRE, MODIFIED TRAILER 064390 TM 5-6115-632-14&P 5 POWER UNIT PU-753/M (NSN 6115-00-033-1 MEP-003A 10 KW 60 HZ GENERATOR SET M116A2 2-WHEEL, 2-TIRE, MODI TRAILER 064392 TM 5-6115-629-14&P 3 POWER PLANT AN/AMJQ-12A (NSN 6115-00-257-1602) (2) MEP-006A 60HZ, GENERATOR SETS (2) M200A1 2-WHEEL, 4-TIRE, MODIFIED TRAIL 064443 TM 5-6115-625-14&P 2 POWER UNIT PU-405A/M (NSN 6115-00-394-9577) MEP-004A 15 KW 60 HZ GENERATOR SET M200A1 2-WHEEL, 4-TIRE, MODIFIED TRAILER (THIS ITEM IS INCLUDED ON EM 0086 & EM 0087) 064445 TM 5-6115-633-14&P 4 POWER PLANT AN/MJQ-18 (NSN 6115-00-033-1398) (2) MEP-003A 1 60 HZ GENERATOR SETS M103A3 2-WHEEL 1 1/2 TON MODIFIED TRAILER 064446 TM 5-6115-628-14&P 4 POWER PLANT AN/MJQ-15 (NSN 6115-00-400-7591) (2) MEP-113A 1 400 HZ GENERATOR SETS, (2) M200A1 2-WHEEL, 4-TIRE, MODIFIED TRA (THIS ITEM IS INCLUDED ON EM 0086) 064542 TM 5-6115-631-14&P 4 POWER PLANT AN/MJQ-16 (NSN 61 15-00-033-1395) (2) MEP-002A 5 KW 60 HZ GENERATOR SETS M103A3 2-WHEEL, 2-TIRE, MODIFIED TRAI 065071 TM 55-1730-229-24P 6 POWER AVIATION, MULTI-OUTPUT GTED ELECTRICAL, HYDAULIC, PNEUMATIC (AG WHEEL MOUNTED, SELF-PROPELLED, TOWABLE AC 400 HZ, 3 PH, 0.8 PF, 115/200V, 30 KW DC 28 VDC 700 AMPS PNEUMATIC 60 LBS/MIN. AT 40 HYDRAULIC 15 GPM AT 3300 PSIG DOD MODEL MEP-360A, CLASS PRECISE 400 HERTZ (NSN 1730-01-144-1897) {TO 35C2-3-473-4; TM 1730-24P/ AG 320A0-IPB-000} 065603 TB 5-6115-593-24 WARRANTY PROGRAM FOR GENERATOR SET DOD MODEL MEP-029A HOUSING K DOD MODEL MEP-029AHK 066727 TM 5-6115-640-14&P 2 POWER AN/MJQ-32 (NSN 6115-01-280-2300) AN/MJQ-33 (6115-01-280-2301) ( MEP-701A 3KW 60 HZ ACOUSTIC SUPPRESSION KIT GENERATOR SETS M116 2-WHEEL, 2-TIRE, 3/4-TON MODIFIED TRAILERS 066808 TM 5-6115-627-14&P 2 POWER PLANT AN/MJQ-10A (NSN 6115-00-394-9582); (2) MEP-005A 30 KW 60 HZ GEN SETS; (2) M200A1 2-WHEEL, 4 TIRE MODIFIED TRAILERS 066809 TM 5-6115-630-14&P 4 POWER UNIT, PU-751/M (NSN 6115-00-033-1373) MEP-002A, 5 KW, 60 HZ GENERATOR SET M116A1 2-WHEEL, 2-TIRE, MODIFIED TRAILER 066824 TM 5-6115-465-10-HR 1 HAND RECEIPT MANUAL COVERING END ITEM/COMPONENTS OF END ITEM (C BASIC ISSUE ITEMS, (BII) AND ADDITIONAL AUTHORIZATION LIST (AAL GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MOUNTED, 30K 4 WIRE, 120/208 AND 240/416 VOLTS - MEP-005A, UTILITY, 50/60 HE (NSN 6115-00-118-1240); MEP-104A, PRECISE, 50/60 HERTZ, (6115-00-118-1247): MEP-114A, PRECISE, 400 HERTZ, (6115-00-118- INCLUDING AUXILIARY EQUIPMENT MEP-005AWF WINTERIZATION KIT, FUE BURNING (6115-00-463-9083); MEP-005AWE, WINTERIZATION KIT, ELEC (6115-00 067310 TM 9-6115-650-14&P 1 POWER PLAN AN/MJQ-25 (NSN 6115-01-153-7742) (2) MEP-112A 10 KW 400 HZ GENE SETS M103A3 2-WHEEL, 2-TIRE, MODIFIED TRAILER 067311 TM 9-6115-653-14&P 2 POWER UNIT PU-732/M (NSN 6115-00-260-3082) MEP-113A 15 KW 400 HZ GENERATOR SET M200 2-WHEEL, 4-TIRE, MODIFIED TRAILER 067544 TM 9-6115-652-14&P 1 POWER UNIT PU-760/M (NSN 6115-00-394-9581) MEP-114A 30 KW 400 HZ GENERATOR M200A1 2-WHEEL, 4-TIRE, MODIFIED TRAILER 067632 TM 9-6115-648-14&P POWER UNIT PU-650B/G (NSN 6115-00-258-1622) MEP-006A 60 KW 60 HZ GENERATOR M200A1 2-WHEEL, 4-TIRE, MODIFIED TRAILER 067744 TM 9-6115-646-14&P 1 POWER UNIT PU-495A/G, (NSN 6115-00-394-9575) AND PU-495B/G, (6115-01-134-0 MEP-007A 100 KW, 60 HZ OR MEP-007B, 100 KW, 60 HZ GENERATOR SET M353-2-WHEEL, 2-TIRE MODIFIED TRAILER 067746 TM 9-6115-651-14&P POWER UNIT 707A/M (NSN 6115-00-394-9573) MEP-115A, 60 KW, 400 HZ GENERATOR M200A1, 2-WHEEL, 4-TIRE, MODIFIED TRAILER 067879 TM 9-6115-647-14&P 1 POWER UNIT PU-789/M (NSN 6115-01-208-9827) MEP-114A, 30 KW 400 HZ GENERATOR SET M353 2-WHEEL, 2-TIRE, MODIFIED TRAILER 069601 TM 9-6115-464-10-HR HAND RECEIPT MANUAL COVERING THE END ITEMS/COMPONENTS OF END IT (COEI), BASIC ISSUE ITEMS (BII), AND ADDITIONAL AUTHORIZATION L (AAL) FOR GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MO 15 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS DOD MODEL MEP UTILITY CLASS, 50/60 HERTZ (NSN 6115-00-118-1241) DOD MODEL MEP PRECISE CLASS, 50/60 HERTZ (6115-00-118-1245) DOD MODEL MEP-113 PRECISE CLASS, 400 HERTZ (6115-00-118-1244) 069602 LO 9-6115-464-12 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL, SKID MTD, 15KW, 4 WIRE, 120/208 AND 240/416 VOLTS (DOD MODEL MEP 004A) (NSN 6115-00-118-1241); (DOD MODEL MEP 104A) (6115-00-118-1245) (DOD MODEL MEP-113A) (6115-00-118-1244) 069954 TM 9-6115-465-24P 2 GENERATOR SET, DIESEL ENGINE DRIVE TACTICAL SKID MTD. 30KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 V MODELS; MEP-005A, UTILITY, 50/60 HZ, (NSN 6115-00-118-1240), MEP-104A PRECISE, 50/60 HZ, (6115-00-118-1247), MEP-114A, PRECISE, 400 H (6115-00-118-1248), INCLUDING OPTIONAL KITS, DOD MODELS; MEP-00 WINTERIZATION KIT, FUEL BURNING, (6115-00-463-9083), MEP-005-AW WINTERIZATION KIT, ELECTRIC, (6115-00-463-9085), MEP-002-ALM, L BANK KIT, (6115-00-463-9088), MEP-005-AWM, WHEEL MOUNTING KIT, (6115-00-463-9094) {TO-35C2-3- 070096 TM 9-6115-464-24P 1 GENERATOR S DIESEL ENGINE DRIVEN, TACTICAL SKID MTD., 15KW, 3 PHASE, 4 WIRE 120/208 AND 240/416 VOLTS (DOD MODEL MEP-004A) UTILITY CLASS 50/60 HERTZ (NSN 6115-00-118-1241) (DOD MODEL MEP-103A) PRECISE CLASS 50/60 HERTZ (6115-00-118-1245) (DOD MODEL MEP-113A) PRECI CLASS 400 HERTZ (6115-00-118-1244) INCLUDING OPTIONAL KITS (DOD MODEL MEP-005-AWF) WINTERIZATION KIT, FUEL BURNING (6115-00-463 (DOD MODEL MEP-005-AWE) WINTERIZATION KIT, ELECTRIC (6615-00-46 (DOD MODEL MEP-004-ALM) LOAD BANK KIT (6115-00-191-9201 071025 TM 9-6115-641-10 2 GENERATOR SET SKID MOUNTED, TACTICAL QUIET 5 KW, 60 AND 400 HZ MEP-802A (60 HZ) (NSN 6115-01-274-7387) MEP-812A (400 HZ) (6115-01-274-7391) {TO 35C2-3-456-11} 071026 TM 9-6115-642-10 2 GENERATOR SET SKID MOUNTED, TACTICAL QUIE 10 KW, 60 AND 400 HZ MEP-803A (60 HZ) (NSN 6115-01-275-5061) MEP-813A (400 HZ) (6115-01-274-7392) {TO 35C2-3-455-11; TM 09247A/09248A-10/1} 071028 TM 9-6115-643-10 3 GENERATOR SET, SKID MOUNTED, TACTICAL QUI 15 KW, 50/60 AND 400 HZ MEP-804A (50/60 HZ) (NSN 6115-01-274-73 MEP-814A (400 HZ) (6115-01-274-7393) {TO 35C2-3-445-21} 071029 TM 9-6115-644-10 2 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 30 KW, 50/60 AND 400 HZ MEP-805A (50/60 HZ), (NSN 6115-01-274-7389) MEP-815A (400 HZ), (6115-01-274-7394) {TO 35C2-3-446-11; TM 09249A/09246A-10/1} 071030 TM 9-6115-645-10 2 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 60 KW, 50/60 AND 400 HZ MEP-806A (50/60 HZ), (NSN 6115-01-274-7390) MEP-816A (400 HZ), (6115-01-274-7395) {TO 35C2-3-444-11; TM 09244A/09245A-10/1} 071031 LO 9-6115-641-12 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 5 KW, 60 AND 400 HZ MEP-802A TACTICAL QUIET 60 HZ (NSN 6115-01-274-7387) MEP-812A TACTICAL QUIET 400 HZ (6115-01-274-7391) 071032 LO 9-6115-642-12 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 10 KW, 60 AND 400 H MEP-803A TACTICAL QUIET 60 HZ (NSN 6115-01-275-5061) MEP-813A TACTICAL QUIET 400 HZ (6115-01-274-7392) 071033 LO 9-6115-643-12 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 15 KW, 50/60/400 HZ MEP-804A TACTICAL QUIET 50/60 HZ (NSN 6115-01-274-7388) MEP-814 TACTICAL QUIET 400 HZ (6115-01-274-7393) 071034 LO 9-6115-644-12 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 30 KW, 50/60 AND 40 MEP-805A TACTICAL QUIET 50/60 HZ (NSN 6115-01-274-7389) MEP-815 TACTICAL QUIET 400 HZ (6115-01-274-7394) {LI 09249A/09246A-12} 071035 LO 9-6115-645-12 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 60 KW, 50/60 AND 40 MEP-806A TACTICAL QUIET 50/60 HZ (NSN 6115-01-274-7390) MEP-816 TACTICAL QUIET 400 HZ (6115-01-274-7395) {LI 09244A/09245A-12} 071036 TB 9-6115-641-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 5 KW, 60 AND 400 HZ MEP-802A AND MEP-812A 071037 TB 9-6115-642-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 10 KW, 60 AND 400 HZ MEP-803A AND MEP-813A {SI 09247A/09248A-24} 071038 TB 9-6115-643-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 15 KW, 50/60 AND 400 HZ MEP-804A AND MEP-814A 071039 TB 9-6115-644-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 30 KW, 50/60 AND 400 HZ MEP-805A AND MEP-815A {SI 09249A/09246A-24} 071040 TB 9-6115-645-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 60 KW, 50/60 AND 400 HZ MEP-806A AND MEP-816A {SI 09244A/09245A-24} 071541 TM 9-6115-464-12 2 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD, 15 KW, 3 PHASE, 4 WIRE, 120/2 AND 240/416 VOLTS DOD MODEL MED-004A UTILITY CLASS 50/60 HERTZ (NSN 6115-00-118-1241) DOD MODEL MEP-103A PRECISE CLASS 50/60 HERTZ (6115-00-118-1245) DOD MODEL MEP-113A PRECISE CLASS 400 HERTZ (6115-00-118-1244) INCLUDING OPTIONAL KITS DOD MODEL MEP-005-AWF WINTERIZATION KIT, FUEL BURNING (6115-00-463-9083) DOD MODEL MEP-005-AWE WINTERIZATION KIT, ELECTRIC (6115-00-463-9085) DOD MODEL MEP-004-ALM LOAD BANK KIT (6115-00-291 071604 TM 9-6115-645-24P GENERATOR SET, TACTICAL QUIET 60KW, 50/60/400 HZ (NSN 6115-01-274-7390) (MEP-806A) (6115-01-274-7395) (MEP-816A) {TO 35C2-3-444-14; TM 09244A/09245A-24P/3} 071605 TM 9-6115-642-24P GENERATOR SET, TACTICAL QUIET 10 KW, 60/400 HZ (NSN 6115-01-275-5061) (MEP-803A) (6115-01-274-7392) (MEP-813A) {TO 35C2-3-455-14; TM 09247A/09248A-24P/3} 071610 TM 9-6115-643-24P GENERATOR SET, TACTICAL QUIET 15KW, 50/60 - 400 HZ (NSN 6115-01-274-7388) (MEP-804A) (6115-01-274-7393) (MEP-814A) {TO 35C2-3-445-24} 071611 TM 9-6115-644-24P GENERATOR SET, TACTICAL QUIET 30KW, 50/60-400 HZ (NSN 6115-01-274-7389) (MEP-805A) (6115-01-274-7394) (MEP-815A) {TO 35C2-3-446-14; TM 09249A/09246A-24P/3} 071613 TM 9-6115-641-24P GENERATOR SET, TACTICAL QUIET 5 KW, 60/400 HZ (NSN 6115-01-274-7387) (MEP-802A) (6115-01-274-7391) (MEP-812A) {TO 35C2-3-456-14} 071713 TM 9-6115-645-24 4 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 60KW, 50/60 AND 400 HZ MEP-806A (50/60 HZ) (NSN 6115-01-274-7390) MEP-816A (400 HZ) (6115-01-274-7395) {TO 35C2-3-444-12; TM 09244A/09245A-24/2} 071748 TM 9-6115-644-24 1 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 30 KW, 50/60 AND 400 HZ MEP-805A (50/60 HZ) (NSN 6115-01-274-7389) MEP-815A (400 HZ) (6115-01-274-7394) {TO 35C2-3-446-12; TM 09249A/09246A-24/2} 071749 TM 9-6115-643-24 4 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 15 KW, 50/60 AND 400 HZ MEP-804A (50/60 HZ) (NSN 6115-01-274-7388) MEP-814A (400 HZ) (6115-01-274-7393) {TO 35C2-3-445-22} 071750 TM 9-6115-642-24 4 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 10 KW, 60 AND 400 HZ MEP-803A (60 HZ) (NSN 6115-01-275-5061) MEP-813A (400 HZ) (6115-01-274-7392) {TO 35C2-3-455-12; TM 09247A/09248A-24/2} 071751 TM 9-6115-641-24 3 GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 5 KW, 60 AND 400 HZ MEP-802A (60 HZ) (NSN 6115-01-274-7387) MEP-812A (400 HZ) (6115-01-274-7391) {TO 35C2-3-456-12} 072239 TM 9-6115-464-34 1 GENERATOR SET, DIESEL ENGINE DRIVEN, TACTICAL SKID MTD., 15 KW, 3 PHASE, 4 WIRE 120/208 AND 240/416 VOLTS DOD MODEL MEP-004A UTILITY CLASS 50/60 HERTZ (NSN 6115-00-118-1241) DOD MODEL MEP 103A PRECISE CLASS 50/60 HERTZ (6115-00-118-1245) DOD MODEL MEP-113A PRECISE CLASS 400 HERTZ (6115-00-118-1244) INCLUDING OPTIONAL KITS DOD MODEL MEP-005AWF WINTERIZATION KIT, FUEL BURNING (6115-00-463-9083) DOD MODEL MEP-005AWE WINTERIZAT KIT, ELECTRIC (6115-00-463-9085) DOD MODEL MEP-004ALM LOAD BANK KIT (6115-00-291-920 073744 TM 9-6115-604-24P 1 GENERATOR SET, DIESEL ENGINE DRIVEN, AIR TRANSPORTABLE SKID MOUNTED, 750KW, 3 PHASE, 4 WIRE, 2400/4160, AND 2200/3800 VOLTS DOD MODEL MEP208A PRIME UTILITY CLASS 50/60 HERTS (NSN 6115-00-450-5881) DOD MODEL 80-1466 REMOTE CONTROL MODULE CLASS (6115-01-150-5284 DOD MODEL 80-7320 SITE REQUIREMENTS MODULE CLASS (6115-01-150-5 {NAVFAC P-8-633-24P} 074040 TM 9-6115-545-24P GENERATOR SET, DIESEL ENGINE DRIVEN, TAC SKID MTD., 60 KW, 3 PHASE, 4 WIRE, 120/208 AND 240/416 VOLTS, D MODELS MEP-006A, UTILITY CLASS, 50/60 H/Z, (NSN 6115-00-118-124 MEP-105A, PRECISE CLASS, 50/60 H/Z, (6115-00-118-1252), MEP-115 PRECISE CLASS, 400 H/Z (6115-00-118-1253); INCLUDING OPTIONAL K DOD MODELS MEP-006AWF, WINTERIZATION FUEL BURNING, (6115-00-407 MEP-006AWE, WINTERIZATION KIT, ELECTRIC, (6115-00-455-7693), ME LOAD BANK KIT, (6115-00-407-8322), AND MEP-006AWM, WHEEL MOUNTI (6115-00-463-9092) {TO 074212 TM 9-6115-604-12 GENERATOR SET, DIESEL DRIVEN, AIR TRANSORTABLE SKID MTD., 750 KW, 3 PHASE, 4 WIRE, 24 AND 2200/3800 V (DOD MODEL MEP 208A) CLASS PRIME UTILITY, HZ 50 (NSN 6115-00-450-5881) {NAVFAC P-8-633-12} 074896 TM 9-6115-604-34 GENERATOR SET, DIESEL ENGINE DRIVEN, AIR TRANSPORTABLE SKID MTD., 750 KW, 3 PHASE, 4 WIRE, 2400/4160 AND 2200/3800 VOLTS DOD MODEL MEP 208A PRIME UTILITY CLASS 50/60 HERTZ (NSN 6115-00-450-5881) {NAVFAC P-8-633-34} 075027 TM 9-6115-584-24P 1 GENERATOR SET, DIESEL E DRIVEN, TACTICAL SKID MTD 5 KW, 1 PHASE -2 WIRE, 1 PHASE -3 WIR 3 PHASE -4 WIRE, 120, 120/240 AND 120/208 VOLTS (DOD MODEL MEP- UTILITY CLASS, 60 HZ (NSN 6115-00-465-1044) {NAVFAC P-8-622-24P TO 35C2-3-456-4} 077581 TM 9-6115-673-13&P 2KW MILITARY TACTICAL GENERATOR SET 120 VAC, 60 HZ (NSN 6115-01-435-1565) (MEP-531A) (EIC: LKA) (NSN 6115-21-912-0393) (MECHRON) 28 VDC (NSN 6115-01-435-1567) (MEP-501A) (EIC: LKD) (NSN 6115-21-912-0392) (MECHRON) 078167 TM 9-6115-672-14 GENERATOR SET SKID MOUNTED TACTICAL QUIET 60KW, 50/60 AND 400 HZ, MEP-806B (50/60 HZ) (NSN 6115-01-462-0291) EIC: GGW, MEP-816B (400 HZ) (NSN 6115-01-462-0292) EIC: GGX 078443 TM 9-6115-639-13 1 3KW TACTICAL QUIET GENERATOR SET MEP 831A (60 HZ) (NSN 6115-01-285-3012) (EIC: VG6) MEP 832A (400 HZ) (NSN 6115-01-287-2431) (EIC: VN7) 078490 TM 9-6115-671-14 OPERATOR, UNIT, GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 30 KW, 50/60 AND 400 HZ, MEP-805B (50/60 HZ) (NSN 6115-01-461-9335) (EIC: GGU) MEP-815B (400 HZ) (6115-01-462-0290) (EIC: GGV) 078503 TM 9-6115-671-24P GENERATOR SET SKID MOUNTED, TACTICAL QUIET 30 KW, 50/60 AND 400 HZ MEP-805B (50/60 HZ) (NSN 6115-01-461-9335) (EIC: GGU) MEP-815B (400 HZ) (NSN 6115-01-462-0290) (EIC: GGV) 078504 TM 9-6115-672-24P GENERATOR SET, SKID MOUNTED, TACTICAL QUIET 60 KW, 50/60 AND 400 HZ MEP-806B (50/60 HZ) (NSN 6115-01-462-0291) (EIC: GGW) MEP-816B (400 HZ) (NSN 6115-01-462-0292 (EIC: GGX) 078505 TB 9-6115-671-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 30KW, 50/60 AND 400 HZ MEP-805B AND MEP-815B PROCURED UNDER CONTRACT DAAK01-96-D-00620WITH MCII INC 078506 TB 9-6115-672-24 WARRANTY PROGRAM FOR GENERATOR SET, TACTICAL QUIET 30KW, 50/60 AND 400 HZ MEP-806B AND MEP-816B PROCURED UNDER CONTRACT DAAK01-96-D-00620WITH MCII INC 078523 TM 9-6115-664-13&P 5KW, 28VDC, AUXILIARY POWER UNIT (APU) MEP 952B NSN 6115-01-452-6513 (EIC: N/A) 078878 TM 9-6115-639-23P 3KW TACTICAL QUIET GENERATOR SET MEP 831A (60 HZ) (NSN 6115-01-285-3012) (EIC: VG6) MEP 832A (400 HZ) (NSN 6115-01-287-2431) (EIC: VN7) 079379 TB 9-6115-641-13 WINTERIZATION KIT (NSN 6115-01-476-8973) INSTALLED ON GENERATOR SET, SKID MOUNTED, TACTICAL QUIET, 5KW, 60 AND 400 HZ MEP-802A (600HZ) (6115-01-274-7387) MEP-812A (400HZ) (6115-01-274-7391) 079460 TB 9-6115-642-13 WINTERIZATION KIT (NSN 6115-01-477-0564) (EIC: N/A) INSTALLED ON GENERATOR KIT, SKID MOUNTED, TACTICAL QUIET, 10KW, 60 AND 400 HZ MEP-803A (60HZ) (6115-01-275-0561) MEP-813A (400HZ) (6115-01-274-7392) 079461 TB 9-6115-643-13 WINTERIZATION KIT (NSN 6115-477-0566) INSTALLED ON GENERATOR SET, SKID MOUNTED, TACTICAL QUIET, 15KW, 50/60 AND 400 HZ, MEP-804A (50/60HZ) (6115-01-274-7388) MEP-814A (400HZ) (6115-01-274-7393) 079462 TB 9-6115-644-13 WINTERIZATION KIT (NSN 6115-01-474-8354) (EIC:N/A) INSTALLED ON GENERATOR SET, SKID MOUNTED, 30KW, 50/60 AND 400 HZ MEP-805A (50/60HZ) (NSN 6115-01-274-7389) MEP-815A (400HZ) (NSN 611501-274-7394) 079463 TB 9-6115-645-13 WINTERIZATION KIT (NSN 6115-01-474-8344) (EIC: N/A) INSTALLED ON GENERATOR SET, SKID MOUNTED, TACTICAL QUIET, 60KW, 50/60 AND 400 HZ, MEP-806A (50/60HZ) (6115-01-274-7390) MEP-816A (400HZ) (6115-01-274-7395) 080214 TM 9-6115-670-14&P AUXILIARY POWER UNIT, 20KW, 120/240 VAC, 60 HZ, MODEL NO. MEP-903A(SICPS) NSN 6115-01-431-3062 MODEL NUMBER MEP-903B (JTACS) NSN 6115-01-431-3063 MODEL NO MEP-903C9WIN-T) NSN 6115-01-458-5329 (EIC: N/A) |
condensing unit wiring diagram: Electricity for Refrigeration, Heating, and Air Conditioning Russell E. Smith, 1983 |
condensing unit wiring diagram: Ice-cream Plant Freezer Capacity 2 1/2 Gallons Per Batch, One Refrigeration Cabinet 80 Gallons Capacity AC, 220/440 Volts, 60 Cycles, FSN 4110-142-1244, FSN 4110-203-1931, FSN 4110-256-7252 United States. Marine Corps, 1961 |
condensing unit wiring diagram: National Guard Bureau Manual United States. National Guard Bureau, 1950 |
condensing unit wiring diagram: War Department Education Manual United States Armed Forces Institute, 1943 |
condensing unit wiring diagram: Operator's, Organizational, Direct Support & General Support Maintenance Manual for Air Conditioner, Horizontal, Compact, 36000 BTUH, 208 Volt, 3 Phase 400 Hertz, NSN 4120-00-063-8182, American Air Filter Co. Model CH436-1 and 208 Volt, 3 Phase, 50/60 Hertz, NSN 4120-00-063-7575, American Air Filter Co. Model CH636-1 , 1986 |
condensing unit wiring diagram: Instrument Landing System Installation Drawings United States. Federal Aviation Administration, 1983 |
condensing unit wiring diagram: Operator, Unit, Intermediate, Direct Support, and Intermediate General Support Maintenance , 1992 |
condensing unit wiring diagram: Refrigerating Engineering , 1958 |
condensing unit wiring diagram: A Practical Facilities Maintenance Handbook Kevin Jones, 2024-09-01 A Practical Facilities Maintenance Handbook has been designed as your go-to source for documents, signage, tags, labels, and reference materials that are commonly used in the facilities maintenance & management space. Since no two facilities are exactly the same, it would be impractical to try and fill this handbook with every possible piece of content that every facility may use. Instead, the content in this handbook is designed to be universal in nature. The purpose of this handbook is to improve workflows, increase productivity and safety of employees and building occupants. The content of this handbook was carefully curated. Examples of commonly used documents included in this handbook are: work order, request for quote, request for proposal, hot work permit, daily forklift inspection, and more. These documents can be photocopied and used as is, or you can scan them into your computer and add your company logo and company details to each form to make them your own. Examples of commonly used signage, tags, and labels included in this handbook are: no parking, closed for maintenance, wet paint, hazmat, lockout/tagout, inspection tags, secondary container tags, and more. These all can be used as is, or printed and laminated, or even printed on sticker paper. Additionally, included in this handbook is an inches-to-millimeters conversion table, wiring schematics, welding, plumbing, and electrical symbols, and 3D isometric drawings of common shop equipment that you can use to fabricate your own shop equipment in house, or send the drawings to your local metal shop to fabricate for your facility. |
condensing unit wiring diagram: Operator's, Organizational, Direct Support, and General Support Maintenance Manual , 1991 |
condensing unit wiring diagram: Electricity for the HVACR Technician CDX Learning Systems, 2018-08-02 Electricity for the HVACR Technician introduces foundational concepts in HVACR electrical systems, guiding students through basic system design and construction to troubleshooting for complex circuits and devices. Combining conceptual electrical knowledge with practical, step-by-step techniques, it equips new technicians with the skills and knowledge necessary to service and repair commercial and residential HVACR systems. |
condensing unit wiring diagram: Black & Decker The Complete Guide to Wiring, 5th Edition , 2011-05 The Complete Guide to Wiring has been America's very best-selling consumer wiring book for more than a decade, with previous editions selling more than 1 million copies. This fifth edition has been updated to comply with 2011-2013 Electrical Codes. It also includes an all new Home Automation chapter, as well as major revisions to lighting and ventilation equipment hookups and new material on working with conduit and raceways. |
condensing unit wiring diagram: BTU Buddy Notebook Bill Johnson, 2008-07-22 The BTU Buddy Notebook is a collection of more than 50 unique service call scenarios conducted by an HVAC technician which describe real-life service scenarios related to troubleshooting. Many high quality images help to illustrate troubleshooting techniques and the equipment being serviced. Important Notice: Media content referenced within the product description or the product text may not be available in the ebook version. |
condensing unit wiring diagram: The Refrigerating Data Book , 1946 |
condensing unit wiring diagram: Electrical Theory and Application for HVACR Randy F Petit Sr., Turner L. Collins, Earl DeLatte, 2012-02-01 With the majority of HVACR service calls being electrical in nature, it is important for technicians to have a solid understanding of electrical fundamentals allowing them to develop a systematic and methodical approach to troubleshooting. Electrical Theory and Application for HVACR provides students and practicing technicians with the information and knowledge necessary to accurately and safely diagnose and solve electrical system faults. Electrical Theory and Application for HVACR was written by HVACR instructors for HVACR instructors to simplify the instruction of electricity. The manual is full of color illustrations and includes worksheets that provide students and practicing technicians with the information and knowledge necessary to accurately and safely diagnose and solve electrical system faults. Main topics include: safety and hazard awareness, electrical fundamentals, motors, circuits and components, wiring diagrams, automated control systems, and troubleshooting. |
condensing unit wiring diagram: Modern Refrigeration and Air Conditioning Andrew Daniel Althouse, Carl Harold Turnquist, Alfred F. Bracciano, 1992 Organized to follow the textbook on a chapter-by-chapter basis, providing questions to help the student review the material presented in the chapter. This supplement is a consumable resource, designed with perforated pages so that a given chapter can be removed and turned in for grading or checking. |
condensing unit wiring diagram: Air Conditioning, Heating and Ventilating , 1959 |
condensing unit wiring diagram: Black & Decker Complete Guide to Wiring, 6th Edition Editors of Cool Springs Press, 2014-05-15 DIVThe best DIY wiring book on the market . . . six times over./divDIV/divDIVBlack & Decker The Complete Guide to Wiring has led the pack as the United States’ best-selling consumer wiring book for more than a decade now, with previous editions selling over one million copies collectively. Simply put, you won’t find a more complete and up-to-date book on home wiring: from basic skills—including an overview of electricity and wiring safety; wire, cable, and conduits; boxes and panels; switches; and receptacles—to foolproof circuit maps for 30 common wiring set-ups and step-by-step walkthroughs of every essential home wiring and electrical repair project, this book teaches you everything you need to know. Now in its sixth edition, it has most importantly been updated to comply with 2014–2017 National Electric Codes, but in addition, nearly 1,000 accompanying photos offer up-to-date depictions of modern materials and fixtures. Complete with the most current wiring information available today, and presented in our long-renowned, fully illustrated how-to format, Black & Decker The Complete Guide to Wiring (6th Edition) guarantees you’ll never be caught in the dark./div |
condensing unit wiring diagram: Black & Decker Advanced Home Wiring Editors of Creative Publishing, 2008-12-15 Includes advanced wiring projects such as installing a subpanel and wiring an outbuilding--Provided by publisher. |
condensing unit wiring diagram: Air Conditioning Refrigerating Data Book , 1956 |
condensing unit wiring diagram: Air conditioning and Refrigeration Repair Made Easy Hooman Gohari, 2009-10-19 This comprehensive book has been developed to quickly train an average person for the vast commercial and residential refrigeration and air-conditioning market within a short period of time. It provides all the technical knowledge needed to start a successful refrigeration and air-conditioning business anywhere in the world. |
condensing unit wiring diagram: Refrigerating Data Book and Catalog American Society of Refrigerating Engineers, 1951 |
condensing unit wiring diagram: Energy Monitoring and Control Systems (EMCS). , 1991 |
condensing unit wiring diagram: Heating, Ventilating, and Air-conditioning Fundamentals Raymond A. Havrella, 1981 |
condensing unit wiring diagram: Operator, Organizational, DS, GS, and Depot Maintenance Manual , 1990 |
condensing unit wiring diagram: Home Heating & Air Conditioning Systems James L. Kittle, 1990-04-22 Detecting faulty installations. Evaluating gas and oil-fires furnaces. Selecting a heating system. Installing an oil-fired furnace. |
condensing unit wiring diagram: Report of Investigations , 1942 |
condensing unit wiring diagram: Cornell Extension Bulletin , 1953 |
condensing unit wiring diagram: High-efficiency Gas Furnace Troubleshooting Handbook Billy C. Langley, 1991 |
condensing unit wiring diagram: Refrigerating Data Book American Society of Refrigerating Engineers, 1955 |
condensing unit wiring diagram: Radio News , 1927 Some issues, 1943-July 1948, include separately paged and numbered section called Radio-electronic engineering edition (called Radionics edition in 1943). |
condensing unit wiring diagram: Specification for the Construction of an Airport Surveillance Radar Facility United States. Federal Aviation Administration, 1975 |
CONDENSING | English meaning - Cambridge Dictionary
CONDENSING definition: 1. present participle of condense 2. to reduce something, such as a speech or piece of writing, in…. Learn more.
CONDENSE Definition & Meaning - Merriam-Webster
The meaning of CONDENSE is to make denser or more compact; especially : to subject to condensation. How to use condense in a sentence. Synonym Discussion of Condense.
CONDENSE Definition & Meaning - Dictionary.com
to reduce to another and denser form, as a gas or vapor to a liquid or solid state. condensed, condensing. to become denser or more compact or concentrated. to reduce a book, speech, …
condense verb - Definition, pictures, pronunciation and usage …
Definition of condense verb from the Oxford Advanced Learner's Dictionary. [intransitive, transitive] to change from a gas into a liquid; to make a gas change into a liquid. condense (into something) …
Condensing - definition of condensing by The Free Dictionary
To concentrate (a substance), especially by removing water. 2. To make more concise; abridge or shorten: condensed the list of guests. 3. To cause (a gas or vapor) to change to a liquid. 1. To …
Condensing - Definition, Meaning & Synonyms - Vocabulary.com
Jun 7, 2025 · DISCLAIMER: These example sentences appear in various news sources and books to reflect the usage of the word ‘condensing'. Views expressed in the examples do not represent …
CONDENSE definition and meaning | Collins English Dictionary
If you condense something, especially a piece of writing or speech, you make it shorter, usually by including only the most important parts. We have learnt how to condense serious messages into …
CONDENSATION Definition & Meaning - Merriam-Webster
: the act or process of condensing. : the quality or state of being condensed. : a chemical reaction involving union between molecules often with elimination of a simple molecule (as water) to form …
What does Condensing mean? - Definitions.net
Condensing is the process by which a substance changes from its gaseous phase to its liquid phase, commonly due to decrease in temperature or increase in pressure. This term can also …
CONDENSE | definition in the Cambridge English Dictionary
CONDENSE meaning: 1. to reduce something, such as a speech or piece of writing, in length: 2. to make a liquid…. Learn more.
Kolpak/RDI Refrigeration System Installation & Operation …
Evaporator Coil Mounting Diagram . www.kolpak.com 800-225-9916 7 Wiring . All electrical connections and routing must comply with local and national codes. Do not ... Condensing unit …
DAIKIN ONE+ Wiring Diagram
DAIKIN ONE+ Wiring Diagram . Ver. Date Changes 1.0 6/17/2019 Support ClimateTalk Unitary Communicating Equipment, including FIT ... CONDENSING UNIT Communicating 2 Stage …
Installer’s Guide Condensing Units - The AC Outlet
water from pouring directly on the unit. STEP 2 - To remove the unit from the pallet, remove tabs by cutting with a sharp tool. Section 3. Unit Preparation 3.1 Prepare The Unit For Installation …
V Series AIR COOLED CONDENSING UNITS 20 TO 80 HP
AIR COOLED CONDENSING UNITS 20 TO 80 HP MODEL NUMBER NOMENCLATURE V C D 30 L 44 - G VOLTAGE V STYLE CONDENSING UNIT V = 208/3/60 W = 230/3/60 FEATURES …
Installation and Table of Contents Operation Manual
wer supply from the condensing unit.po See unit cooler spec. plate for ampacity. w voltage - 24V Class II control circuit. A total of five • Lo w voltage leads are required to connect the …
Installation and Operation Manual - BOHN
3 Compressor Module Specifications Table 1. Hermetic Compressor Module Electrical Data Hermetic Compressor Compressor Data Crankcase Compressor Electrical Rating RLA = …
AIR COOLED CONDENSER -INSTALLATION AND OPERATION …
1 AIR COOLED CONDENSER -INSTALLATION AND OPERATION MANUAL- 8167 Byron Road Whittier, CA 90606 Phone: (562) 945-8971 Fax: (562) 696-0724 www.compu-aire.com
WCCU Series Condensing Units - Jetson
condensing unit is equipped with a shell-and-tube type, water cooled condenser. All units are shipped with a holding charge of dry nitrogen. Units are dehydrated, leak tested, and controls …
Installer’s Guide Condensing Units - Trane Heating & Air …
3.1 Prepare The Unit For Installation STEP 1 - Check for damage and report prompt-ly to the carrier any damage found to the unit. Section 4. Setting the Unit 4.1 Pad Installation When …
R-410A MODELS: YC090 Through 300 YD120 Through 240
26 Typical YC090 Condensing Unit Wiring Diagram . . . . . 36 27 Typical YE090 Condensing Unit Wiring Diagram . . . . . 37 28 Typical YC120 - 150 Condensing Unit Wiring Diagram . 38 29 …
Closed tanks, DX Milk Cooling Tank w Hygenius
System Book Closed tanks, DX Milk Cooling Tank w Hygenius 0205 92564101
Optyma™ condensing units
Optyma™ condensing units Catalog www.danfoss.us/aftermarket Easy installation, easy service and reliable performance
Wiring Diagrams - The AC Outlet
Wiring Diagrams 127A Preferredt Series 2--Stage Air Conditioner with Puronr Refrigerant 2--5Tons 336323-101 REV. A CONNECTION DIAGRAM COMP OFM S C R BRN BLK YEL BLK …
TECHNICAL The 10 SEER Series condensing unit is the …
The 10 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus-tom-matched with one of UPG’s complete line of evaporator sections, …
INSTALLATION INSTRUCTIONS - Carrier
35” Tall, High Efficiency Condensing Gas Furnace (F/G)9MVE These instructions must be read and understood completely before attempting installation. Safety Labeling and Signal Words …
Single Condenser Defrost Time Clock Board - Copeland
Figure 3 - Wiring Diagram. 026-4834 R2 ©2024 Copeland LP. 4 The rewiring of the evaporator will vary based on the type of evaporator. The typical rewiring sequence is shown in the …
2021 USER MANUAL - Copeland
Steam condensing unit user manual. 2 TABLE OF CONTENTS Page Introduction, scope, disclaimer 3 Safety information 4 Nomenclature 6 Features & benefits 6 ... In case of …
wiring diagrams 561C, G 561S, W - shareddocs.com
wiring diagrams 1 AND 3 PHASE, 60 HERTZ AIR CONDITIONING UNIT Cancels: WD 561C.18.6 WD 561C.18.7 1-05 561C, G 561S, W
WALK-IN COOLER AND FREEZER INSTALLATION AND …
5 NOTE TO ELECTRICIAN All freezer doors come pre-assembled with a heat wire fully installed. It is the installers responsibility to verify that all the conduit connections are sealed with caulk …
TEZ New Generation D Condensing Units - uri
Unit SmartSpeed Condensing Unit with SmartSpeed Power Consumption Per Motor Chassis Size (see pages 31-35) Ambients above 55°F. Fan Full Speed. Crankcase and Receiver Heaters …
ZX condensing unit - Copeland
the wiring diagram supplied with each unit takes precedence over the diagram in this manual. Introduction to ZX platform CDU ZX medium temperature, ZXD digital medium temperature …
Installation and Operation Manual - Heatcraft Refrigeration …
Condensing Unit Rigging Rigging Holes Figure 3. Condensing Unit Rigging Adequate rigging measures must be taken to support unit weight and to protect the unit from damage during …
Installation and Table of Contents Operation Manual
power supply from the condensing unit. See unit cooler spec. plate for ampacity. • Low voltage - 24V Class II control circuit. A total of five low voltage leads are required to connect the …
Large Air-Cooled Condensing Units - Hussmann, a …
4 LARGE AIR-COOLED CONDENSING UNITS Specifications subject to change without notice. CONDENSING UNIT MODEL COMPRESSOR CONDENSER 0 5 10 15 20 25 30 35 40 45 …
Copeland Scroll IZSI condensing unit for refrigeration …
wiring diagram supplied with each unit takes precedence over the diagram in this manual. Important: The information contained in this manual is critical to the correct operation and …
Replaces H-IM-80E (06-17) Installation and Operation Manual
Wiring Wiring All 24 volt wiring must be run separate from the line voltage wiring . All low voltage wiring must be 18 gauge minimum and must be run separate from high voltage wiring . The …
92-104921-07 Rev. 01 RA17 Air Conditioning Unit Installation …
CONDENSING UNITS 92-104921-07-01 (6/15) Printed in USA [ ] indicates metric conversions. ... EcoNet Communication System™ Control Wiring 22 ... The condensing unit is designed to …
WIRING DIAGRAMS - Carrier Enterprise
NON-COMMUNICATING OUTDOOR UNIT BLK RED TRAN ECM ECM PCB 208 V 24 V 230 V BRN COM RED TRAN U S E GRN RED BLU YEL 1. Use Copper Wire (75ºC Min) Only …
ConDenSing unitS manual - EMI & RetroAire
8. Check wiring diagram for the required number of low voltage wires to be run between indoor and outdoor sections. Completed electrical Connections S1C S1C Shown S1C S1C Shown 9. …
Beacon II™ Refrigeration Systems - Imperial Brown
Wiring Wiring between the condensing unit and the unit cooler(s) will be as follows (see wiring diagrams): • High voltage - There may be high voltage on the defrost heater relay and the fan …
90-23238-01 Rev. 13 Wiring Diagram - pts.myrheem.com
Title: 90-23238-01 Rev. 13 Wiring Diagram Author: rdmgr Subject: Remote Wiring Diagram for Single Stage, Single Phase Remote Air Conditioning Condensing Unit
Installation and maintenance condensing unit manual
• Store the unit between -30 °F and 120 °F. • Don’t expose the packaging to rain or corrosive atmosphere. • After unpacking, check that the unit is complete and undamaged. Introduction …
CONDENSING UNIT & KUCB EVKUCB EVKUCB …
the condensing unit to the evaporator. (see note on wiring diagram). OPTION 3 - Alternate Timeclock Wiring If the fan motor or defrost heater amperages require fusing greater than 15A …
Installation, Start-Up and Service Instructions - Carrier
Before performing service or maintenance operations on unit, turn off main power switch to unit and install lock(s) and lock-out tag(s). Ensure electrical service to rooftop unit agrees with …
R-410A MODELS: J07 Through 25YC J07YE J10 Through …
5734684-JIM-B-0519 4 Johnson Controls Ducted Systems Physical Data Table 1: J07 through 25YC, J07YE, and J10 through 20YD Physical Data Component
MultiCon REMOTE AIR COOLED CONDENSER - HTPG
Divide the BTUH THR by the design condensing temperature of 15°F TD. (TD = Condensing Temperature - Ambient Temperature) 385,700 ÷ 15 = 25,713 BTUH per 1°F TD Convert BTUH …
Water-cooled scroll condensing unit - Copeland
In case of ambiguity, the wiring diagram supplied with each unit takes precedence over the diagram in this manual. 2204/MEA/R/3/xx/107. Water cooled scroll condensing unit. 5 1. Safety …
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
the system wiring diagram (provided in the condensing unit). Connection to TB1-44 must be made to assure proper pumpdown function.The room thermostat is mounted on the unit cooler for …
Split System Remote Condensing Units and EVP Chillers
Typical Field Control Wiring Diagram for "Variable Air Volume" Application..... 8 Figure 5 Typical Field Control Wiring Diagram for "EVP" ... R = Remote Condensing Unit E = 200/60/3 XL 0 = …
Application Engineering BULLE T IN AE8-1376 R2 - Copeland
2.1 Condensing Unit Installation Instructions A condensing unit with an Electronic Unit Controller will be installed exactly the same as a condensing unit with mechanical controls. Customer …
Condensing Units Table of Contents - Heatcraft Refrigeration …
Low Profile Unit Cooler (LOP) - 55°F. Medium Profile Unit Cooler (MP) - 55°F Center Mount Unit Cooler (CM) - 85°F Large Unit Cooler (LUC) - 55°F Low Velocity Center Mount Unit Cooler …
Operating Instructions & Service Manual - Everidge
Apr 21, 2020 · part of the condensing unit. The other main component of the condensing unit is the con-denser, which is the aluminum-finned coil also located on the roof. The condenser is …
Wiring Diagrams - Carrier
Fig. 1 – Wiring Diagram — Model sizes 1--1/2 -- 5 tons, 208/230--1. 2 336751-101 REV. A CONDENSING UNIT CHARGING INSTRUCTIONS CAUTION For use with units using R-410A …
Split System Air Conditioners Odyssey with Symbio Controls
SSA-SVX06L-EN 5 Model Number Description Air Handler Digit 1, 2, 3 — Unit Function TWE = Air Handler Digit 4, 5, 6— Tonnage 051 = 4.6 Tons (50Hz) 060 = 5 Tons (60 Hz)
INSTALLER'S GUIDE Condensing Units 4TTA3 - Trane Heating …
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa-tion pack upon completion of work. ... Trane outdoor condensing units are …
Installation and Operation Manual - Heatcraft Refrigeration …
The condensing unit control panel contains the relays, contactors, time delay and a terminal block which is appropriately marked to match the low voltage wiring connections. A sensor for …
Wiring Diagrams - Carrier
Wiring Diagrams INDEX UNIT 50BYN V-PH-Hz LABEL DIAGRAM FIG. NUMBER 006 008 208/230-3-60 460-3-60 11720011-C 1 575-3-60 012 208/230-3-60 014 460-3-60 11720960-B 2 …
TECHNICAL INFORMATION TI Unit Fan 02 EN Rev00 …
TI_Unit_Fan_02_EN_Rev00 TECHNICAL INFORMATION ... Most fans can be equipped with a speed controller connected to the condensing pressure. Application Engineering Europe 3/9 3 …
M Series
1/2 To 6 HP Indoor & Outdoor Condensing Units Features & Benefits Typical Outdoor Hermetic Unit Typical Outdoor Unit with throwaway liquid-line filter and sight glass Typical Outdoor …
Commercial Split System 6 to 12 Installation Chart 6, 7 - Carrier
4. MAKE ELECTRICAL CONNECTIONS 5. UNIT PRE-START PRE START-UP TIPS 1 - Verify that power is off, locked out and tagged off. 2 - Route power wiring from disconnect through …